Repository logoCyprus University of Technology
Log In(current)
Ελληνικά
English
  1. Home
  2. Cyprus University of Technology (Research Output)
  3. Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation
  4. Metallic stents: Biomechanical analysis and in vivo investigation of the vessel inflammatory response
  • Details

Metallic stents: Biomechanical analysis and in vivo investigation of the vessel inflammatory response

Date Issued
April 1, 2016
Author(s)
Kapnisis, Konstantinos  
Pitsillides, Costas  
Prokopi, Marianna  
Constantinides, Georgios  
Cristea, Daniel  
Munteanu, Daniel  
Brott, Brigitta C.  
Anderson, Peter G.  
Lemons, Jack  
Anayiotos, Andreas  
DOI
10.1007/978-3-319-32703-7_213
Abstract
Despite a considerable clinical and investigative emphasis on the problem of in-stent restenosis (ISR), complications arising from the interaction of stent materials with the surrounding vessel wall as well as from the mechanical forces developing during and after implantation, remain a significant problem. Nanoindentation studies performed on various locations along the stent struts have shown that the hardness of specific stent locations significantly increases after mechanical expansion. The increase in hardness was associated with a reduction of the material‘s ability to dissipate energy in plastic deformations and therefore with an increased vulnerability to fracture and fatigue. It was concluded that the locations of fatigue fractures in stent struts are controlled not only by the geometrically-driven stress concentrations developing during cyclic loading but also by the local material mechanical changes that are imparted on various parts of the stent during the deployment process. Additionally, the project focused on investigating the effect of stent corrosion in an animal model in order to explore a possible link between metal ion release, inflammation and factors thought to initiate ISR. To evaluate the vessel inflammatory response, stents with active corrosion were implanted in mice abdominal aortas and novel in vivo imaging techniques were employed to assess the trafficking and accumulation of fluorescent donor monocytes as well as the proliferation of vascular smooth muscle cells at the implantation site. The in vivo imaging analysis revealed that elevated metal particle contamination, prompted by corroded stents, triggers an inflammatory response and promotes monocyte recruitment with upregulation of MMPs at the site of injury.
Subjects

Animal model

Biomechanical testing...

In vivo imaging

In-stent restenosis

Stents

Explore by
  • Collections
  • Research Outputs
  • Researchers
  • Faculty & Departments
  • Theses
  • Patents
  • Projects
  • Journals
  • Conferences
Useful Links
  • Researcher Portfolio Guide
  • Researcher Profile
  • Create an ORCID ID
  • CUT Open Access Author Fund
  • ETDS Guide
Copyright Policies

Use Sherpa/Romeo to find publisher copyright policies

Go
Go
  • SPARC Author Addendum Engine
  • National Open Access Policy in Cyprus
Deposit your work to Ktisis
  • Self-archiving. Please sign in to Ktisis.
  • Email your work to:
    library.dspace@cut.ac.cy
  • Contact your subject librarian

Member of

OpenAIREre3dataOpenDOARCOREDART
Cyprus University of Technology
Library and
Information
Services

Copyright © 2022 - Library and Information Services Feedback - Built with DSpace-CRIS - 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
COAR NotifyCOAR Notify