Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/2395
DC FieldValueLanguage
dc.contributor.authorKalli, Kyriacos-
dc.contributor.authorAllsop, Thomas P.-
dc.contributor.authorDobb, Helen L.-
dc.date.accessioned2013-02-20T12:06:06Zen
dc.date.accessioned2013-05-17T05:29:46Z-
dc.date.accessioned2015-12-02T11:21:58Z-
dc.date.available2013-02-20T12:06:06Zen
dc.date.available2013-05-17T05:29:46Z-
dc.date.available2015-12-02T11:21:58Z-
dc.date.issued2006-
dc.identifier.citationProgress in Biomedical Optics and Imaging - Proceedings of SPIE, 6083, art. no. 60830S; Optical Fibers and Sensors for Medical Diagnostics and Treatment Applications VI,21-22 January 2006,San Jose,Californiaen_US
dc.identifier.issn1605-7422-
dc.description.abstractA set of long period grating devices have been fabricated in photosensitive single mode fibre coated with a series of copper rings (period of 380μm, 50% duty cycle and length of 4cm). The long period gratings were inscribed with a uniform UV-laser exposure across the entire length of the copper ring patterned coating. The devices ranged in copper thickness from 0.5μm to 1.5μm. In addition, a control long period grating was fabricated in the same type of fibre with the same period for comparison. The refractive index and temperature spectral sensitivity of these devices were investigated and it was found that the index and temperature sensitivity is a function of the thickness of the copper rings, as supported by theoretical modelling. Furthermore, the index sensitivity of these devices in the 1.333 index region is greater than the control long period grating. The patterned 0.5μm coated long period grating gave a sensitivity of Δλ/Δn = -74 nm leading to a resolution of 1.4×10-3 compared to the control which had a sensitivity of Δλ/Δn = -32 nm with a resolution of 3.2×10-3 in the index region of 1.320 to 1.380 (aqueous solution regime). This demonstrates a two fold increase in the sensitivity. This novel fibre long period grating device shows potential for increasing the resolution of measurements of the index of aqueous solutions.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.rights© 2006 SPIE.en_US
dc.subjectCoatingsen_US
dc.subjectCopperen_US
dc.subjectDiffraction gratingsen_US
dc.subjectRefractive indexen_US
dc.subjectOptical fibersen_US
dc.titleEnhanced spectral sensitivity of fibre long period gratings to refractive index of aqueous solutions utilising copper patterned coatingsen_US
dc.typeConference Papersen_US
dc.affiliationHigher Technical Institute Cyprusen
dc.collaborationCyprus University of Technologyen_US
dc.subject.categoryElectrical Engineering - Electronic Engineering - Information Engineeringen_US
dc.countryCyprusen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
dc.relation.conferenceOptical Fibers and Sensors for Medical Diagnostics and Treatment Applications VIen_US
dc.identifier.doi10.1117/12.647515en_US
dc.dept.handle123456789/54en
cut.common.academicyear2019-2020en_US
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_c94f-
item.openairetypeconferenceObject-
item.languageiso639-1en-
crisitem.author.deptDepartment of Electrical Engineering, Computer Engineering and Informatics-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0003-4541-092X-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation
CORE Recommender
Show simple item record

Page view(s) 50

443
Last Week
1
Last month
9
checked on May 12, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.