Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/2395
Τίτλος: Enhanced spectral sensitivity of fibre long period gratings to refractive index of aqueous solutions utilising copper patterned coatings
Συγγραφείς: Kalli, Kyriacos 
Allsop, Thomas P. 
Dobb, Helen L. 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Λέξεις-κλειδιά: Coatings;Copper;Diffraction gratings;Refractive index;Optical fibers
Ημερομηνία Έκδοσης: 2006
Πηγή: Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 6083, art. no. 60830S; Optical Fibers and Sensors for Medical Diagnostics and Treatment Applications VI,21-22 January 2006,San Jose,California
Conference: Optical Fibers and Sensors for Medical Diagnostics and Treatment Applications VI 
Περίληψη: A set of long period grating devices have been fabricated in photosensitive single mode fibre coated with a series of copper rings (period of 380μm, 50% duty cycle and length of 4cm). The long period gratings were inscribed with a uniform UV-laser exposure across the entire length of the copper ring patterned coating. The devices ranged in copper thickness from 0.5μm to 1.5μm. In addition, a control long period grating was fabricated in the same type of fibre with the same period for comparison. The refractive index and temperature spectral sensitivity of these devices were investigated and it was found that the index and temperature sensitivity is a function of the thickness of the copper rings, as supported by theoretical modelling. Furthermore, the index sensitivity of these devices in the 1.333 index region is greater than the control long period grating. The patterned 0.5μm coated long period grating gave a sensitivity of Δλ/Δn = -74 nm leading to a resolution of 1.4×10-3 compared to the control which had a sensitivity of Δλ/Δn = -32 nm with a resolution of 3.2×10-3 in the index region of 1.320 to 1.380 (aqueous solution regime). This demonstrates a two fold increase in the sensitivity. This novel fibre long period grating device shows potential for increasing the resolution of measurements of the index of aqueous solutions.
ISSN: 1605-7422
DOI: 10.1117/12.647515
Rights: © 2006 SPIE.
Type: Conference Papers
Affiliation: Higher Technical Institute Cyprus 
Affiliation: Cyprus University of Technology 
Εμφανίζεται στις συλλογές:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

Page view(s) 20

443
Last Week
2
Last month
9
checked on 11 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα