Τίτλος: | A comparison of ultrasound intima media thickness measurements of the left and right common carotid artery | Συγγραφείς: | Loizou, Christos P. Pattichis, Constantinos S. Georghiou, Niki Griffin, Maura B. Nicolaides, Andrew N. |
Major Field of Science: | Engineering and Technology | Field Category: | Medical Engineering | Λέξεις-κλειδιά: | Ultrasonic imaging;Image segmentation;Ultrasonic variables measurement;Carotid arteries | Ημερομηνία Έκδοσης: | 9-Ιαν-2014 | Πηγή: | 13th IEEE International Conference on BioInformatics and BioEngineering, 2013, 10-13 November, Chania, Greece | Conference: | IEEE International Conference on Bioinformatics and Bioengineering | Περίληψη: | The intima-media thickness (IMT) of the common carotid artery (CCA) is an established indicator of cardiovascular disease (CVD). There have been reports about the difference between the left and the right sides of the CCA IMT and its importance when evaluated with various risk factors as well as their association with the risk of stroke. In this study, we use an automated system based on snakes, for segmenting the CCA and perform measurements of the IMT of the carotid artery and provide their differences between the left and right sides. The study was performed on 205 longitudinal-section ultrasound images acquired from 87 men and 118 women at a mean±SD age of 63±10.47 years, out of which 51 had cardiovascular symptoms. A cardiovascular expert manually measured the IMT on the left CCA side (mean±standard deviation = 0.79±0.21 mm) and the right CCA side (0.76±0.33 mm). The left and right IMT automated measurements were 0.70±0.15 mm and 0.66±0.15 mm, respectively. We found no statistical significant differences: 1) between the left and right IMT measurements, for both the manual and automated measurements, and 2) between the manual and automated measurements for both sides. These findings suggest that the measurement of the CCA IMT on one side only is enough (and this is in agreement with other studies), as well as automated measurements can be used. | URI: | https://hdl.handle.net/20.500.14279/23669 | ISBN: | 978-1-4799-3163-7 | DOI: | 10.1109/BIBE.2013.6701666 | Rights: | © IEEE | Type: | Conference Papers | Affiliation: | Intercollege University of Cyprus Vascular Screening and Diagnostic Center |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation |
CORE Recommender
SCOPUSTM
Citations
50
4
checked on 14 Μαρ 2024
Page view(s) 50
294
Last Week
1
1
Last month
2
2
checked on 3 Ιαν 2025
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons