Τίτλος: A comparison of ultrasound intima media thickness measurements of the left and right common carotid artery
Συγγραφείς: Loizou, Christos P. 
Pattichis, Constantinos S. 
Georghiou, Niki 
Griffin, Maura B. 
Nicolaides, Andrew N. 
Major Field of Science: Engineering and Technology
Field Category: Medical Engineering
Λέξεις-κλειδιά: Ultrasonic imaging;Image segmentation;Ultrasonic variables measurement;Carotid arteries
Ημερομηνία Έκδοσης: 9-Ιαν-2014
Πηγή: 13th IEEE International Conference on BioInformatics and BioEngineering, 2013, 10-13 November, Chania, Greece
Conference: IEEE International Conference on Bioinformatics and Bioengineering 
Περίληψη: The intima-media thickness (IMT) of the common carotid artery (CCA) is an established indicator of cardiovascular disease (CVD). There have been reports about the difference between the left and the right sides of the CCA IMT and its importance when evaluated with various risk factors as well as their association with the risk of stroke. In this study, we use an automated system based on snakes, for segmenting the CCA and perform measurements of the IMT of the carotid artery and provide their differences between the left and right sides. The study was performed on 205 longitudinal-section ultrasound images acquired from 87 men and 118 women at a mean±SD age of 63±10.47 years, out of which 51 had cardiovascular symptoms. A cardiovascular expert manually measured the IMT on the left CCA side (mean±standard deviation = 0.79±0.21 mm) and the right CCA side (0.76±0.33 mm). The left and right IMT automated measurements were 0.70±0.15 mm and 0.66±0.15 mm, respectively. We found no statistical significant differences: 1) between the left and right IMT measurements, for both the manual and automated measurements, and 2) between the manual and automated measurements for both sides. These findings suggest that the measurement of the CCA IMT on one side only is enough (and this is in agreement with other studies), as well as automated measurements can be used.
URI: https://hdl.handle.net/20.500.14279/23669
ISBN: 978-1-4799-3163-7
DOI: 10.1109/BIBE.2013.6701666
Rights: © IEEE
Type: Conference Papers
Affiliation: Intercollege 
University of Cyprus 
Vascular Screening and Diagnostic Center 
Εμφανίζεται στις συλλογές:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations 50

4
checked on 14 Μαρ 2024

Page view(s)

239
Last Week
2
Last month
11
checked on 11 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons Creative Commons