Abstract: In this paper we compare four different snakes segmentation methods for segmenting the athrerosclerotic carotid plaque from longitudinal ultrasound images of the carotid artery. The accuracy and reproducibility of the methods were tested on 80 images and the results were compared with the manual delineations of an expert. The comparison showed that the Lai&Chin snakes segmentation method gave better results with the true positive fraction, TPF, true negative fraction TNF, Williams index, KI, and overlap index, to be 82.70%, 80.89%, 80.66%, and 69.30% respectively. Better false negative fraction, FNF, and false positive fraction, FPF, were given by the Balloon method with 13.90% and, 5.40% respectively.
URI: https://hdl.handle.net/20.500.14279/23662
ISSN: 1727-1983
Rights: © IFMBE
Type: Conference Papers
Affiliation : Intercollege 
University of Cyprus 
Cyprus Institute of Neurology and Genetics 
Vascular Screening and Diagnostic Center 
Publication Type: Peer Reviewed
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

CORE Recommender
Show full item record

Page view(s)

222
Last Week
0
Last month
2
checked on Dec 22, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons