Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/22694
Τίτλος: | Experimental performance of a parabolic trough collector system for an industrial process heat application | Συγγραφείς: | Ktistis, Panayiotis K. Agathokleous, Rafaela Kalogirou, Soteris A. |
Major Field of Science: | Engineering and Technology | Field Category: | Environmental Engineering | Λέξεις-κλειδιά: | PTC;Steam production;Solar collector;Concrete storage | Ημερομηνία Έκδοσης: | 15-Ιαν-2021 | Πηγή: | Energy, 2021, vol. 215, part A, articl. no. 118177 | Volume: | 215 | Issue: | part A | Περιοδικό: | Energy | Περίληψη: | Manufacturing is responsible for 60% of the fuel consumption in Cyprus and the industrial sector is the second biggest fuel consumer, mainly for steam production. Thus, the use of parabolic trough collector (PTC) systems for the production of steam or hot water can be a promising solution for the industrial sector. This study presents the first industrial PTC system in Cyprus, installed at the biggest soft drinks factory. The system consists of 288 m2 of PTC, a steam generator and concrete thermal energy storage (CTES) in order to keep the system dispatchable. To achieve that, two operation strategies are developed which are controlled automatically by the main processor of the system. The first strategy is enabled when there is a steam demand and the second when the energy can be stored directly to the CTES. Both strategies are tested, and it is shown that under Strategy 1 the PTC system can produce 940 litters of steam per day, and under Strategy 2 it can store 107.3 kWhth. In two months period tests, it is proved that it can supply the required amount of steam to the factory even when solar radiation is low, with the support from the CTES. | Description: | The authors regret to realise a typing mistake on page 3, line 9. The number of 280 kWth should be 280 kWhth. Additionally, there is a problem in Fig. 5. The correct figure and the correct legend of the figure are as shown below: [Figure presented] Fig. 5. (a) Steam generator (b) feed water tanks (c) variable speed pump (d) control valves. The authors would like to apologise for any inconvenience caused. | URI: | https://hdl.handle.net/20.500.14279/22694 | ISSN: | 03605442 | DOI: | 10.1016/j.energy.2020.119288 | Rights: | © The Author(s). This is an open access article under the CC BY-NC-ND license. Attribution-NonCommercial-NoDerivatives 4.0 International |
Type: | Article | Affiliation: | Cyprus University of Technology | Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
1-s2.0-S0360544220323951-main.pdf | Fulltext | 3.9 MB | Adobe PDF | Δείτε/ Ανοίξτε |
1-s2.0-S0360544221001249-main.pdf | Erratum | 542.43 kB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
24
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
21
Last Week
0
0
Last month
2
2
checked on 29 Οκτ 2023
Page view(s)
338
Last Week
1
1
Last month
14
14
checked on 21 Νοε 2024
Download(s)
232
checked on 21 Νοε 2024
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons