Τίτλος: The effects of stenting on hemorheological parameters: An in vitro investigation under various blood flow conditions
Συγγραφείς: Kapnisis, Konstantinos 
Seidner, H 
Prokopi, Marianna 
Pasias, Dimitris 
Pitsillides, Costas 
Anayiotos, Andreas 
Kaliviotis, Efstathios 
Major Field of Science: Engineering and Technology
Field Category: Mechanical Engineering
Λέξεις-κλειδιά: Blood viscosity;Cardiovascular stent;Lysis;Red blood cell aggregation;Red blood cell deformability
Ημερομηνία Έκδοσης: 2019
Πηγή: Clinical Hemorheology and Microcirculation, 2019, vol. 72, no. 4, pp. 375-393
Volume: 72
Issue: 4
Start page: 375
End page: 393
Περιοδικό: Clinical hemorheology and microcirculation 
Περίληψη:  Despite their wide clinical usage, stent functionality may be compromised by complications at the site of implantation, including early/late stent thrombosis and occlusion. Although several studies have described the effect of fluid-structure interaction on local haemodynamics, there is yet limited information on the effect of the stent presence on specific hemorheological parameters. The current work investigates the red blood cell (RBC) mechanical behavior and physiological changes as a result of flow through stented vessels. Blood samples from healthy volunteers were prepared as RBC suspensions in plasma and in phosphate buffer saline at 45% haematocrit. Self-expanding nitinol stents were inserted in clear perfluoroalkoxy alkane tubing which was connected to a syringe, and integrated in a syringe pump. The samples were tested at flow rates of 17.5, 35 and 70 ml/min, and control tests were performed in non-stented vessels. For each flow rate, the sample viscosity, RBC aggregation and deformability, and RBC lysis were estimated. The results indicate that the presence of a stent in a vessel has an influence on the hemorheological characteristics of blood. The viscosity of all samples increases slightly with the increase of the flow rate and exposure. RBC aggregation and elongation index (EI) decrease as the flow rate and exposure increases. RBC lysis for the extreme cases is evident. The results indicate that the stresses developed in the stent area for the extreme conditions could be sufficiently high to influence the integrity of the RBC membrane.
URI: https://hdl.handle.net/20.500.14279/16153
ISSN: 13860291
DOI: 10.3233/CH-180540
Rights: © IOS
Type: Article
Affiliation: Cyprus University of Technology 
University College London 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

2
checked on 2 Φεβ 2024

WEB OF SCIENCETM
Citations

1
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s) 50

366
Last Week
2
Last month
34
checked on 30 Απρ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα