Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/14177
Title: Investigation on the thermographic detection of corrosion in RC structures
Authors: Tantele, Elia 
Votsis, Renos 
Kyriakides, Christopher 
Georgiou, Panagiota G. 
Ioannou, Fotia G. 
Major Field of Science: Engineering and Technology
Field Category: Civil Engineering
Keywords: Corrosion;Infrared thermography;Non-destructive testing (NDT);Reinforced concrete (RC) structures
Issue Date: 1-Jan-2017
Source: 5th International Conference on Remote Sensing and Geoinformation of the Environment, RSCy 2017, Paphos, Cyprus, 20 March 2017 through 23 March 2017
Conference: International Conference on Remote Sensing and Geoinformation of the Environment 
Abstract: © 2017 SPIE. Corrosion of the steel reinforcement is the main problem of reinforced concrete (RC) structures. Over the past decades, several methods have been developed aiming to detect the corrosion process early in order to minimise the structural damage and consequently the repairing costs. Emphasis was given in developing methods and techniques of non-destructive nature providing fast on-the-spot detection and covering large areas rather that concentrating on single locations. This study, investigates a non-destructive corrosion detection technique for reinforced concrete, which is based on infrared thermography and the difference in thermal characteristics of corroded and non-corroded steel rebars. The technique is based on the principle that corrosion products have poor heat conductivity, and they inhibit the diffusion of heat that is generated in the reinforcing bar due to heating. For the investigation RC specimens, have been constructed in the laboratory using embedded steel bars of different corrosion states. Afterward, one surface of the specimens was heated using an electric device while thermal images were captured at predefined time instants on the opposite surface with an IR camera. The test results showed a clear difference between the thermal characteristics of the corroded and the non-corroded samples, which demonstrates the potential of using thermography in corrosion detection in RC structures.
Description: Proceedings of SPIE - The International Society for Optical Engineering, Volume 10444, 2017, Article number 104441M
URI: https://hdl.handle.net/20.500.14279/14177
ISSN: 0277786X
DOI: 10.1117/12.2281183
Type: Conference Papers
Affiliation : Cyprus University of Technology 
Appears in Collections:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

CORE Recommender
Show full item record

SCOPUSTM   
Citations

2
checked on Mar 14, 2024

Page view(s)

312
Last Week
1
Last month
21
checked on Apr 28, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.