Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/14052
Title: Nanometer-sized ceria-coated silica-iron oxide for the reagentless microextraction/preconcentration of heavy metals in environmental and biological samples followed by slurry introduction to ICP-OES
Authors: Dados, A 
Paparizou, E 
Eleftheriou, Polyvios 
Papastephanou, C 
Stalikas, C D 
Major Field of Science: Engineering and Technology
Field Category: Mechanical Engineering
Keywords: Heavy metals microextraction/preconcentration; Inductively coupled plasma-optical emission spectrometry; Nanometer-sized magnetic ceria; Slurry suspension sampling;Inductively coupled plasma-optical emission spectrometry;Nanometer-sized magnetic ceria;Slurry suspension sampling
Issue Date: Apr-2014
Source: Talanta,2014, vol. 121, App. 127-135
Volume: 121
Start page: 127
End page: 135
Journal: Talanta 
Abstract: A slurry suspension sampling technique is developed and optimized for the rapid microextraction of heavy metals and analysis using nanometer-sized ceria-coated silica-iron oxide particles and inductively coupled plasma optical emission spectrometry (ICP-OES). Magnetic-silica material is synthesized by a co-precipitation and sol-gel method followed by ceria coating through a precipitation. The large particles are removed using a sedimentation-fractionation procedure and a magnetic homogeneous colloidal suspension of ceria-modified iron oxide-silica is produced for microextraction. The nanometer-sized particles are separated from the sample solution magnetically and analyzed with ICP-OES using a slurry suspension sampling approach. The ceria-modified iron oxide-silica does not contain any organic matter and this probably justifies the absence of matrix effect on plasma atomization capacity, when increased concentrations of slurries are aspirated. The As, Be, Mo, Cr, Cu, Pb, Hg, Sb, Se and V can be preconcentrated by the proposed method at pH 6.0 while Mn, Cd, Co and Ni require a pH ≥ 8.0. Satisfactory values are obtained for the relative standard deviations (2-6%), recoveries (88-102%), enrichment factors (14-19) and regression correlation coefficients as well as detectability, at sub-μg L(-1) levels. The applicability of magnetic ceria for the microextraction of metal ions in combination with the slurry introduction technique using ICP is substantiated by the analysis of environmental water and urine samples.
ISSN: 18733573
DOI: 10.1016/j.talanta.2013.12.045
Rights: © Elsevier
Type: Article
Affiliation : Cyprus University of Technology 
University of Ioannina 
Cp Foodlab Ltd. 
Publication Type: Peer Reviewed
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

SCOPUSTM   
Citations

36
checked on Feb 1, 2024

WEB OF SCIENCETM
Citations

35
Last Week
1
Last month
1
checked on Oct 29, 2023

Page view(s)

304
Last Week
0
Last month
2
checked on Dec 3, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.