Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/13884
Τίτλος: | Positioning device for MRI-guided high intensity focused ultrasound system | Συγγραφείς: | Milonas, Nicos Damianou, Christakis A. Ioannides, Kleanthis |
Major Field of Science: | Engineering and Technology | Field Category: | Electrical Engineering - Electronic Engineering - Information Engineering | Λέξεις-κλειδιά: | MRI;Positioning;Robot;Ultrasound | Ημερομηνία Έκδοσης: | 1-Ιαν-2008 | Πηγή: | International Journal of Computer Assisted Radiology and Surgery, 2008, vol 2, no. 6, pp. 335-345 | Volume: | 2 | Issue: | 6 | Start page: | 335 | End page: | 345 | Περιοδικό: | International Journal of Computer Assisted Radiology and Surgery | Περίληψη: | Objective: A prototype magnetic resonance imaging (MRI)- compatible positioning device was used to move an MRI-guided high intensity focused ultrasound (HIFU) transducer. The positioning device has three user-controlled degrees of freedom that allow access to various targeted lesions. Materials and methods: The positioning device was designed and fabricated using construction materials selected for compatibility with high magnetic fields and fast switching magnetic field gradients encountered inside MRI scanners. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, plastic sheets, brass screws, plastic pulleys and timing belts. The HIFU/MRI system includes the multiple subsystems (a) HIFU system, (b) MR imaging, (c) Positioning device (robot) and associate drivers, (d) temperature measurement, (e) cavitation detection, (f) MRI compatible camera, and (g) Soft ware. Results: The MRI compatibility of the system was successfully demonstrated in a clinical high-field MRI scanner. The ability of the robot to accurately move the transducer thus creating discrete and overlapping lesions in biological tissue was tested successfully. Conclusion: A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can use either a lateral or superior-inferior approach. Discrete and large lesions were created successfully with reproducible results. © CARS 2008. | ISSN: | 18616410 | DOI: | 10.1007/s11548-007-0145-x | Rights: | © Springer | Type: | Article | Affiliation: | Frederick University Medsonic Ltd Ygia Polyclinic Hospital |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
20
checked on 14 Μαρ 2024
WEB OF SCIENCETM
Citations
16
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s)
369
Last Week
0
0
Last month
30
30
checked on 14 Μαρ 2025
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα