Title: | Stent overlapping and geometric curvature influence the structural integrity and surface characteristics of coronary nitinol stents | Authors: | Halwani, Dina O. Anayiotos, Andreas Kapnisis, Konstantinos |
metadata.dc.contributor.other: | Αναγιωτός, Ανδρέας Καπνίσης, Κωνσταντίνος |
Major Field of Science: | Medical and Health Sciences | Field Category: | Industrial Biotechnology | Keywords: | Corrosion and anti-corrosives;Fatigue;Coronary arteries--Stenosis--Relapse;Scanning electron microscopy | Issue Date: | Apr-2013 | Source: | Journal of the Mechanical Behavior of Biomedical Materials, 2013, vol. 20, pp. 227-236 | Volume: | 20 | Start page: | 227 | End page: | 236 | Journal: | Journal of the Mechanical Behavior of Biomedical Materials | Abstract: | Preliminary studies have revealed that some stents undergo corrosion and fatigue-induced fracture in vivo, with significant release of metallic ions into surrounding tissues. A direct link between corrosion and in-stent restenosis has not been clearly established; nonetheless in vitro studies have shown that relatively high concentrations of heavy metal ions can stimulate both inflammatory and fibrotic reactions, which are the main steps in the process of restenosis. To isolate the mechanical effects from the local biochemical effects, accelerated biomechanical testing was performed on single and overlapping Nickel-Titanium (NiTi) stents subjected to various degrees of curvature. Post testing, stents were evaluated using Scanning Electron Microscopy (SEM) to identify the type of surface alterations. Fretting wear was observed in overlapping cases, in both straight and curved configurations. Stent strut fractures occurred in the presence of geometric curvature. Fretting wear and fatigue fractures observed on stents following mechanical simulation were similar to those from previously reported human stent explants. It has been shown that biomechanical factors such as arterial curvature combined with stent overlapping enhance the incidence and degree of wear and fatigue fracture when compared to single stents in a straight tube configuration. | URI: | https://hdl.handle.net/20.500.14279/4383 | ISSN: | 17516161 | DOI: | 10.1016/j.jmbbm.2012.11.006 | Rights: | © Elsevier | Type: | Article | Affiliation : | Cyprus University of Technology University of Alabama at Birmingham |
Publication Type: | Peer Reviewed |
Appears in Collections: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
10
41
checked on Nov 9, 2023
WEB OF SCIENCETM
Citations
33
Last Week
0
0
Last month
0
0
checked on Oct 29, 2023
Page view(s)
526
Last Week
1
1
Last month
1
1
checked on Jan 3, 2025
Google ScholarTM
Check
Altmetric
Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.