Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/4383
Τίτλος: | Stent overlapping and geometric curvature influence the structural integrity and surface characteristics of coronary nitinol stents | Συγγραφείς: | Halwani, Dina O. Anayiotos, Andreas Kapnisis, Konstantinos |
metadata.dc.contributor.other: | Αναγιωτός, Ανδρέας Καπνίσης, Κωνσταντίνος |
Major Field of Science: | Medical and Health Sciences | Field Category: | Industrial Biotechnology | Λέξεις-κλειδιά: | Corrosion and anti-corrosives;Fatigue;Coronary arteries--Stenosis--Relapse;Scanning electron microscopy | Ημερομηνία Έκδοσης: | Απρ-2013 | Πηγή: | Journal of the Mechanical Behavior of Biomedical Materials, 2013, vol. 20, pp. 227-236 | Volume: | 20 | Start page: | 227 | End page: | 236 | Περιοδικό: | Journal of the Mechanical Behavior of Biomedical Materials | Περίληψη: | Preliminary studies have revealed that some stents undergo corrosion and fatigue-induced fracture in vivo, with significant release of metallic ions into surrounding tissues. A direct link between corrosion and in-stent restenosis has not been clearly established; nonetheless in vitro studies have shown that relatively high concentrations of heavy metal ions can stimulate both inflammatory and fibrotic reactions, which are the main steps in the process of restenosis. To isolate the mechanical effects from the local biochemical effects, accelerated biomechanical testing was performed on single and overlapping Nickel-Titanium (NiTi) stents subjected to various degrees of curvature. Post testing, stents were evaluated using Scanning Electron Microscopy (SEM) to identify the type of surface alterations. Fretting wear was observed in overlapping cases, in both straight and curved configurations. Stent strut fractures occurred in the presence of geometric curvature. Fretting wear and fatigue fractures observed on stents following mechanical simulation were similar to those from previously reported human stent explants. It has been shown that biomechanical factors such as arterial curvature combined with stent overlapping enhance the incidence and degree of wear and fatigue fracture when compared to single stents in a straight tube configuration. | URI: | https://hdl.handle.net/20.500.14279/4383 | ISSN: | 17516161 | DOI: | 10.1016/j.jmbbm.2012.11.006 | Rights: | © Elsevier | Type: | Article | Affiliation: | Cyprus University of Technology University of Alabama at Birmingham |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
10
41
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
33
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s)
526
Last Week
1
1
Last month
1
1
checked on 3 Ιαν 2025
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα