Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/4383
Τίτλος: Stent overlapping and geometric curvature influence the structural integrity and surface characteristics of coronary nitinol stents
Συγγραφείς: Halwani, Dina O. 
Anayiotos, Andreas 
Kapnisis, Konstantinos 
metadata.dc.contributor.other: Αναγιωτός, Ανδρέας
Καπνίσης, Κωνσταντίνος
Major Field of Science: Medical and Health Sciences
Field Category: Industrial Biotechnology
Λέξεις-κλειδιά: Corrosion and anti-corrosives;Fatigue;Coronary arteries--Stenosis--Relapse;Scanning electron microscopy
Ημερομηνία Έκδοσης: Απρ-2013
Πηγή: Journal of the Mechanical Behavior of Biomedical Materials, 2013, vol. 20, pp. 227-236
Volume: 20
Start page: 227
End page: 236
Περιοδικό: Journal of the Mechanical Behavior of Biomedical Materials 
Περίληψη: Preliminary studies have revealed that some stents undergo corrosion and fatigue-induced fracture in vivo, with significant release of metallic ions into surrounding tissues. A direct link between corrosion and in-stent restenosis has not been clearly established; nonetheless in vitro studies have shown that relatively high concentrations of heavy metal ions can stimulate both inflammatory and fibrotic reactions, which are the main steps in the process of restenosis. To isolate the mechanical effects from the local biochemical effects, accelerated biomechanical testing was performed on single and overlapping Nickel-Titanium (NiTi) stents subjected to various degrees of curvature. Post testing, stents were evaluated using Scanning Electron Microscopy (SEM) to identify the type of surface alterations. Fretting wear was observed in overlapping cases, in both straight and curved configurations. Stent strut fractures occurred in the presence of geometric curvature. Fretting wear and fatigue fractures observed on stents following mechanical simulation were similar to those from previously reported human stent explants. It has been shown that biomechanical factors such as arterial curvature combined with stent overlapping enhance the incidence and degree of wear and fatigue fracture when compared to single stents in a straight tube configuration.
URI: https://hdl.handle.net/20.500.14279/4383
ISSN: 17516161
DOI: 10.1016/j.jmbbm.2012.11.006
Rights: © Elsevier
Type: Article
Affiliation: Cyprus University of Technology 
University of Alabama at Birmingham 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

41
checked on 9 Νοε 2023

WEB OF SCIENCETM
Citations

33
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s) 10

520
Last Week
0
Last month
3
checked on 4 Οκτ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα