Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/3664
Τίτλος: First outbreak of nosocomial legionella infection in term neonates caused by a cold mist ultrasonic humidifier
Συγγραφείς: Yiallouros, Panayiotis K. 
Papadouri, Thalia 
Karaoli, Christina 
Papamichael, Elena 
Zeniou, Maria 
Pieridou-Bagatzouni, Despo 
Papageorgiou, George T. 
Pissarides, Nicholas 
Harrison, Timothy G. 
Hadjidemetriou, Andreas 
Major Field of Science: Medical and Health Sciences
Field Category: Clinical Medicine
Λέξεις-κλειδιά: Legionellosis;Neonates;Outbreak;Respiratory equipment
Ημερομηνία Έκδοσης: 19-Μαρ-2013
Πηγή: Clinical Infectious Diseases, 2013, vol. 57, no. 1, pp. 48-56
Volume: 57
Issue: 1
Start page: 48
End page: 56
Περιοδικό: Clinical Infectious Diseases 
Περίληψη: Background To date, all descriptions of legionellosis in neonates have emerged from a small number of isolated case reports in newborns with unusually severe pneumonia. In December 2008, a large outbreak of Legionella infection occurred in term neonates in Cyprus, providing new information on the epidemiological and clinical features of Legionellosis in this age group.Methods An environmental investigation was performed at a small private hospital where the infected neonates were delivered. The medical records of the infected neonates were retrospectively reviewed to obtain clinical data on presentation, complications, and course of disease.Results Nine of the 32 (28%) newborns who were exposed to the contaminated source at the private nursery were infected with Legionella. Six subjects had pulmonary infiltrates, but in 3 cases there were no abnormal radiological findings and clinical presentation was mild. In 4 neonates, pulmonary infiltrates at presentation were bilateral and extensive and 3 died, conferring a mortality rate of 50% in subjects with pulmonary infiltrates and an overall mortality of 33.3%. Legionella pneumophila serogroup 3 was recovered in neonatal biological samples, although in some patients there was implication of a second strain, serogroup 1. It was determined that the neonates were infected while in the nursery at the private hospital by aerosol produced by a recently installed cold-mist humidifier that was filled with contaminated water.Conclusions Use of humidifiers in nursery units must be avoided as the risk of disseminating Legionella in neonates is very high. In neonates legionellosis should be suspected when signs of infection first appear and take an unusual course, even when no pulmonary infiltrates appear.
URI: https://hdl.handle.net/20.500.14279/3664
ISSN: 15376591
DOI: 10.1093/cid/cit176
Rights: © Oxford
Type: Article
Affiliation: Cyprus University of Technology 
Hospital Archbishop Makarios III 
Nicosia General Hospital 
State General Laboratory 
Health Protection Agency 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

52
checked on 9 Νοε 2023

WEB OF SCIENCETM
Citations 20

43
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s)

491
Last Week
0
Last month
12
checked on 21 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα