Repository logoCyprus University of Technology
Log In(current)
Ελληνικά
English
  1. Home
  2. Cyprus University of Technology (Research Output)
  3. Άρθρα/Articles
  4. Evaluation of the optimum insulation thickness of building external walls and roof based on human thermal comfort criterion
  • Details

Evaluation of the optimum insulation thickness of building external walls and roof based on human thermal comfort criterion

Journal
Renewable Energy
Date Issued
July 1, 2025
Author(s)
Axaopoulos, Petros J.  
Sakellariou, Evangelos I.  
Panayiotou, Gregoris P.  
Kalogirou, Soteris A.  
DOI
10.1016/j.renene.2025.123058
Abstract
The need to save energy in the buildings is a key priority, as buildings consume the largest share of energy and have the greatest potential for energy savings. A large amount of this energy consumed, is used for heating and cooling of the buildings. One of the measures that contributes substantially to energy savings in housing is the appropriate thermal insulation material of the exterior walls and the building envelope in general. However, determining the optimal insulation thickness (OpIT) based on economic indicators, such as net present value or pay-back period, has high degree of uncertainty due to the impossibility of accurately predicting future energy prices. In addition, considering one set-point temperature for the winter and another for the summer season does not ensure thermal comfort inside the dwelling. In the present study, a criterion based on the human thermal comfort index was used, to determine the optimal thickness of the insulation of the external walls and roof. Thus, a dynamic thermal simulation of a typical house, using hourly weather data of Athens-Greece and Larnaca-Cyprus was performed, and an optimization algorithm was used to determine the optimal insulation thickness for the roof and for each wall individually. In addition, for the calculation of the outdoor heat transfer coefficient, the wind speed and direction have been taken into account. For the considered typical house and the corresponding climatic data, the OpIT was found to range from 2.9 cm to 13.9 cm for Athens and from 3.2 cm to 14 cm for Larnaca for the east wall and roof respectively. This new approach to determine the optimal insulation thickness showed that proposed method can be utilized ensuring a comfortable and pleasant environment inside the building, for 8512 h and 8506 h during the year for Athens and Larnaca respectively.
Subjects

Human thermal comfort...

Optimum insulation th...

Predicted mean vote (...

Predicted percentage ...

Wind speed and direct...

Explore by
  • Collections
  • Research Outputs
  • Researchers
  • Faculty & Departments
  • Theses
  • Patents
  • Projects
  • Journals
  • Conferences
Useful Links
  • Researcher Portfolio Guide
  • Researcher Profile
  • Create an ORCID ID
  • CUT Open Access Author Fund
  • ETDS Guide
Copyright Policies

Use Sherpa/Romeo to find publisher copyright policies

Go
Go
  • SPARC Author Addendum Engine
  • National Open Access Policy in Cyprus
Deposit your work to Ktisis
  • Self-archiving. Please sign in to Ktisis.
  • Email your work to:
    library.dspace@cut.ac.cy
  • Contact your subject librarian

Member of

OpenAIREre3dataOpenDOARCOREDART
Cyprus University of Technology
Library and
Information
Services

Copyright © 2022 - Library and Information Services Feedback - Built with DSpace-CRIS - 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
COAR NotifyCOAR Notify