Repository logoCyprus University of Technology
Log In(current)
Ελληνικά
English
  1. Home
  2. Cyprus University of Technology (Research Output)
  3. Άρθρα/Articles
  4. On the broken rotor bar diagnosis using time-frequency analysis: 'Is one spectral representation enough for the characterisation of monitored signals?'
  • Details

On the broken rotor bar diagnosis using time-frequency analysis: 'Is one spectral representation enough for the characterisation of monitored signals?'

Journal
IET Electric Power Applications
Date Issued
July 1, 2019
Author(s)
Panagiotou, Panagiotis A.  
Arvanitakis, Ioannis  
Lophitis, Neophytos  
Antonino-Daviu, Jose A.  
Gyftakis, Konstantinos N.  
DOI
10.1049/iet-epa.2018.5512
Abstract
This work enhances the knowledge of the diagnostic potential of the broken bar fault in induction motors. Since a series of studies have been published over the years regarding condition monitoring and fault diagnostics of these machines, it is essential to reach a common ground on why - sometimes - different techniques render different results. In this context, an investigation is provided with regards to the optimal window that should be adopted for the implementation of a proper time-frequency analysis of the monitored signals. On this agenda, this study attempts to set lower and upper bound limits for proper windowing from the digital signal processing point of view. This is done by proposing a formula for the lower limit, which is derived according to the specific frequencies one desires to put under inspection and which are the fault-related signatures. Finally, a discussion on the upper bound is put onwards; results from finite-element simulations are examined with the discussed approach in both the transient regime and the steady state, while experimental results verify the simulations with satisfying accuracy.
Subjects

Condition monitoring

Induction motors

broken rotor bar

File(s)
Thumbnail Image
Name

IET Electric Power Appl - 2019 - Panagiotou - On the broken rotor bar diagnosis using time frequency analysis Is one.pdf

Size

4.97 MB

Format

Adobe PDF

Checksum (MD5)

9a458a4c6a6c969ab5b9afbfeaf13926

Explore by
  • Collections
  • Research Outputs
  • Researchers
  • Faculty & Departments
  • Theses
  • Patents
  • Projects
  • Journals
  • Conferences
Useful Links
  • Researcher Portfolio Guide
  • Researcher Profile
  • Create an ORCID ID
  • CUT Open Access Author Fund
  • ETDS Guide
Copyright Policies

Use Sherpa/Romeo to find publisher copyright policies

Go
Go
  • SPARC Author Addendum Engine
  • National Open Access Policy in Cyprus
Deposit your work to Ktisis
  • Self-archiving. Please sign in to Ktisis.
  • Email your work to:
    library.dspace@cut.ac.cy
  • Contact your subject librarian

Member of

OpenAIREre3dataOpenDOARCOREDART
Cyprus University of Technology
Library and
Information
Services

Copyright © 2022 - Library and Information Services Feedback - Built with DSpace-CRIS - 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
COAR NotifyCOAR Notify