Title: Computationally-efficient high-fidelity nonlinear FEA of seismically isolated post-tensioned RC bridges
Authors: Markou, George 
AlHamaydeh, Mohammad 
Major Field of Science: Engineering and Technology
Field Category: Computer and Information Sciences;ENGINEERING AND TECHNOLOGY;Civil Engineering
Keywords: Full-Scale Bridge Modeling;Simulation;Nonlinear Analysis Finite Element Analysis (NLFEA);Prestressing;Elastomeric Bearing
Issue Date: 1-Feb-2024
Source: Structures, 2024, vol.60
Volume: 60
Journal: Structures 
Abstract: This study presents a novel computationally efficient high-fidelity nonlinear FEA (NLFEA) methodology for prestressed RC bridges constructed in the UAE and seismically isolated with elastomeric bearings. Specifically, the presented NLFEA methodology, using 3D solid brick elements, is shown to overcome traditional prohibitive numerical burdens. This is demonstrated without compromising accuracy or upscaling applicability and appropriateness. The proposed NLFEA approach is highlighted through detailed modeling of RC bridges’ non-traditional structural components and loading aspects (elastomeric bearings and post-tension prestressing cables). The mechanical behavior of elastomeric isolators and the RC continua, including cracking and other nonlinear phenomena, are captured via 3D solid brick elements. Moreover, the modeling procedure accurately represents the post-tension tendons’ prestressing forces and the associated effects on the RC elements. The prestressing forces are incorporated within the tendon elements via insightful manipulations of stepwise initial conditions and internal force adjustments. Additionally, load-carrying capacity determination for the elastomeric bearings was achieved by conducting a parametric investigation to capture their mechanical behavior adequately. Eventually, the analysis of a full-scale bridge is presented in this paper. The post-tensioned RC bridge understudy spans 100 m over eight elastomeric (natural rubber) seismic isolator bearings. Twelve post-tension prestressing cables are utilized to provide the bridge with continuous internal tension-balancing forces. A high-fidelity detailed FEA model of the complete bridge is developed and validated against a SAP2000 FEA model. It is shown that reasonable computational efforts can be expected without compromising the accuracy of the results.
URI: https://hdl.handle.net/20.500.14279/33071
ISSN: 23520124
DOI: 10.1016/j.istruc.2023.105816
Type: Article
Affiliation : University of Pretoria 
American University of Sharjah 
Publication Type: Peer Reviewed
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

Page view(s)

28
Last Week
2
Last month
19
checked on Dec 3, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.