Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/33042
Τίτλος: Enhanced dynamic simulation approach towards the efficient mining thermal energy supply with improved operational flexibility
Συγγραφείς: Rosado-Tamariz, Erik 
Genco, Filippo 
Campos-Amezcua, Alfonso 
Markou, George 
Batres, Rafael 
Major Field of Science: Engineering and Technology
Field Category: Computer and Information Sciences;ENGINEERING AND TECHNOLOGY;Civil Engineering
Λέξεις-κλειδιά: Combined heat and power;Copper mining;Dynamic simulation;Electrowinning;OpenModelica simulations;Operational flexibility;Power plant retrofitting
Ημερομηνία Έκδοσης: 10-Μαρ-2021
Πηγή: International Journal of Energy Research, 2021 vol.45 n.3
Volume: 45
Issue: 3
Περιοδικό: International Journal of Energy Research 
Περίληψη: This paper presents a thermal power plant retrofitting approach focused on improvements in the operational flexibility of existing combined cycle power plants dedicated to providing thermal energy for medium and low-temperature processes in copper mining facilities. The main motivation for this research was aimed at evaluating the operational flexibility of the electrical industry through sector coupling and its effect on solving the energy sector decarbonization issues. The research evaluates the advantages of hybridization systems for supporting the electrical and mining industries to better predict operations. The proposed approach is based on a dynamic simulation scheme that finds the optimal operating parameters of the combined heat and power (CHP) system, such as location, type, and arrangement of each component of the CHP system. The power plant dynamic simulation model was validated against data available in the literature; it was also characterized by real operational data of the San Isidro II power plant installed in Chile. Several alternatives for the cogeneration plant location, as well as the splitter system design, were investigated and then compared. A cogeneration plant design with two heating modules was selected based on the comparative study performed in this work and its CHP system was evaluated for a load reduction case study. The results were compared against a reference model. The proposed CHP system exhibited improved performance: a minimum of 15% of the exhaust gases are required to supply the thermal energy demand of the electrowinning process when a full load is considered. It was also found that an average decrease of 5% of the mechanical power at each steam turbine stage noted. Finally, the proposed CHP system's average thermodynamic efficiency is found to be 19% greater than the power plant average efficiency. Consequently, an average decrease of 32 500 tons of carbon dioxide emissions per year is predicted.
URI: https://hdl.handle.net/20.500.14279/33042
ISSN: 0363907X
DOI: 10.1002/er.6089
Type: Article
Affiliation: University of Pretoria 
Tecnológico de Monterrey 
Ontario Tech University 
Instituto Nacional de Electricidad y Energías Limpias (INEEL) 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

Page view(s)

7
checked on 18 Οκτ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα