Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/33000
Title: | Effect of Different Endodontic Access Cavity Designs in Combination with WaveOne Gold and TruNatomy on the Fracture Resistance of Mandibular First Molars: A Nonlinear Finite Element Analysis | Authors: | Vorster, Martin Gravett, Dewald Zane van der Vyver, Peet J. Markou, George |
Major Field of Science: | Engineering and Technology | Field Category: | Computer and Information Sciences;ENGINEERING AND TECHNOLOGY;Medical Engineering | Keywords: | Access cavity; TruNatomy; WaveOne Gold; conservative endodontic access; nonlinear finite element analysis; traditional endodontic access | Issue Date: | May-2023 | Source: | Journal of Endodontics, 2023, vol.49 no.5, pp. 559-566 | Volume: | 49 | Issue: | 5 | Start page: | 559 | End page: | 566 | Journal: | Journal of Endodontics | Abstract: | This study evaluated the effect of traditional and conservative endodontic access cavity designs in combination with WaveOne Gold and TruNatomy instrumentation systems on the fracture resistance of mandibular first molars by means of nonlinear finite element analysis (FEA). | URI: | https://hdl.handle.net/20.500.14279/33000 | ISSN: | 00992399 | DOI: | 10.1016/j.joen.2023.03.004 | Type: | Article | Affiliation : | University of Pretoria | Publication Type: | Peer Reviewed |
Appears in Collections: | Άρθρα/Articles |