Micro-pillar sensor based wall-shear mapping in pulsating flows: In-situ calibration and measurements in an aortic heart-valve tester

Journal
Journal of Fluids and Structures
Date Issued
August 1, 2021
Author(s)
Li, Qianhui  
Stavropoulos-Vasilakis, Evangelos  
Koukouvinis, Foivos (Phoevos)  
Gavaises, Manolis  
Bruecker, Christoph H.  
DOI
10.1016/j.jfluidstructs.2021.103346
Abstract
Accurate wall-shear stress (WSS) in-vitro measurements within complex geometries such as the human aortic arch under pulsatile flow are still difficult to achieve, meanwhile such data are important for classifying impacts of prosthetic valves on aortic walls. Micro-cantilever beams can serve to sense the WSS in such flows for applications in in-vitro flow tester. However, within pulsatile flows and complex 3D curved geometries such as the aortic arch, the flexible sensor structures are subject to oscillating boundary layer thickness and profile shape, which may not have been taken into account in the calibration procedure. The fluid–structure interaction is sensitive to these changes, thus reflecting also the flow-induced deflection of the sensor tip which is actually the sensing signal. We develop herein a methodology for in-situ calibration of the response of the sensors directly in the complex geometry of the aortic arch, assisted by reference data from numerical simulations of the flow under the same boundary conditions. For this procedure, a quick exchange of the heart valve in the tester with a tubular insert is done to provide a smooth contour in the curved aorta model. Arrays of 500 μm long micro-pillar WSS sensors in the aorta model are calibrated under physiological pulsatile flow and used then for mapping the WSS evolution in the arch induced by two different heart valve, showing their difference of impact. The developed methodology completes the in-house built in-vitro flow tester with a reliable WSS measurement technique and provides a unique hydrodynamic testing facility for heart valve prostheses and their impact on the WSS distal along the aortic walls.
Subjects

Aorta

CFD-assisted calibrat...

Heart-valve tester

Micro-pillar sensors

Pulsating flow

Wall shear stress

Explore by
  • Collections
  • Research Outputs
  • Researchers
  • Faculty & Departments
  • Theses
  • Patents
  • Projects
  • Journals
  • Conferences
Useful Links
  • Researcher Portfolio Guide
  • Researcher Profile
  • Create an ORCID ID
  • CUT Open Access Author Fund
  • ETDS Guide
Copyright Policies

Use Sherpa/Romeo to find publisher copyright policies

Go
Go
  • SPARC Author Addendum Engine
  • National Open Access Policy in Cyprus
Deposit your work to Ktisis
  • Self-archiving. Please sign in to Ktisis.
  • Email your work to:
    library.dspace@cut.ac.cy
  • Contact your subject librarian

Member of

OpenAIREre3dataOpenDOARCOREDART
Cyprus University of Technology
Library and
Information
Services

Copyright © 2022 - Library and Information Services Feedback - Built with DSpace-CRIS - 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
COAR NotifyCOAR Notify