Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/23783
Τίτλος: CO2 absorption in flat membrane microstructured contactors of different wettability using aqueous solution of NaOH
Συγγραφείς: Constantinou, Achilleas 
Barrass, Simon 
Gavriilidis, Asterios 
Major Field of Science: Natural Sciences
Field Category: Chemical Sciences
Λέξεις-κλειδιά: CO2 capture;Membrane contactor;Microstructured contactor;NaOH absorbent
Ημερομηνία Έκδοσης: 1-Δεκ-2018
Πηγή: Green Processing and Synthesis, 2018, vol. 7, no. 6, pp. 471–476
Volume: 7
Issue: 6
Start page: 471
End page: 476
Περιοδικό: Green Processing and Synthesis 
Περίληψη: CO2 absorption in solutions of sodium hydroxide (NaOH) was performed in three membrane/mesh microstructured contactors: a single-channel polytetrafluoroethylene (PTFE) membrane contactor, a nickel mesh contactor and an eight-channel PTFE membrane contactor. A membrane/mesh was used to achieve gas/liquid mass transfer without dispersion of one phase within the other. The PTFE membrane consisted of a pure PTFE layer 20 μm thick laminated onto a polypropylene (PP) layer of 80 μm thickness. The pure PTFE layer contained pores of ~0.5 to 5 μm diameter and was hydrophobic, while the PP layer consisted of rectangular openings of 0.8 mm×0.324 mm and was hydrophilic. The nickel mesh was 25 μm thick and contained pores of 25 μm diameter and was hydrophilic. Experiments were performed with a 2 m NaOH solution and an inlet feed of 20 vol % CO2/N2 gas mixture. Numerical simulations matched reasonably well the experimental data. CO2 removal efficiency increased by increasing the NaOH concentration, the gas residence time and the exchange area between gas and liquid. Higher removal of CO2 was achieved when the PP was in the gas side rather than in the liquid side, due to lower mass transfer resistance of the gas phase. For the same reason, CO2 removal efficiency was higher for the eight-channel PTFE contactor compared to the nickel mesh contactor. Average CO2 flux was higher for the eight-channel contactor (8×10-3 mol/min·cm2 with PP on the gas side) compared to the nickel mesh contactor (3×10-3 mol/min·cm2) for the same gas and liquid residence times. The eight-channel PTFE membrane contactor removed around 72% of CO2 in 1.2 s gas residence time, demonstrating the potential for CO2 absorption using flat membrane contactors.
URI: https://hdl.handle.net/20.500.14279/23783
ISSN: 21919550
DOI: 10.1515/gps-2017-0024
Type: Article
Affiliation: University College London 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Άρθρα/Articles

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
10.1515_gps-2017-0024.pdfFulltext439.69 kBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

7
checked on 14 Μαρ 2024

WEB OF SCIENCETM
Citations

6
Last Week
0
Last month
1
checked on 29 Οκτ 2023

Page view(s) 20

449
Last Week
1
Last month
8
checked on 8 Νοε 2024

Download(s)

206
checked on 8 Νοε 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα