Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/23596
Title: | Segmentation of the common carotid intima-media complex in ultrasound images using active contours | Authors: | Petroudi, Styliani H. Loizou, Christos P. Pantziaris, Marios Pattichis, Constantinos S. |
Major Field of Science: | Engineering and Technology | Field Category: | Medical Engineering | Keywords: | Active contours;Carotid artery;Intima-media thickness;Level sets;Segmentation;Ultrasound imaging | Issue Date: | Nov-2012 | Source: | IEEE Transactions on Biomedical Engineering, 2012, vol. 59, no. 11, pp. 3060-3069 | Volume: | 59 | Issue: | 11 | Start page: | 3060 | End page: | 3069 | Journal: | IEEE Transactions on Biomedical Engineering | Abstract: | The segmentation of the intima-media complex (IMC) of the common carotid artery (CCA) wall is important for the evaluation of the intima media thickness (IMT) on B-mode ultrasound (US) images. The IMT is considered an important marker in the evaluation of the risk for the development of atherosclerosis. The fully automated segmentation algorithm presented in this article is based on active contours and active contours without edges and incorporates anatomical information to achieve accurate segmentation. The level set formulation by Chan and Vese using random initialization provides a segmentation of the CCA US images into different distinct regions, one of which corresponds to the carotid wall region below the lumen and includes the far wall IMC. The segmented regions are used to automatically achieve image normalization, which is followed by speckle removal. The resulting smoothed lumen-intima boundary combined with anatomical information provide an excellent initialization for parametric active contours that provide the final IMC segmentation. The algorithm is extensively evaluated on 100 different cases with ground truth (GT) segmentation available from two expert clinicians. The GT mean IMT value is 0.6679 mm +/ - 0.1350 mm and the corresponding automatically segmented (AS) mean IMT value is 0.6054 mm +/ - 0.1464 mm. The mean absolute difference between the GT IMT and the IMT evaluated from from the AS region is 0.095 mm +/ - 0.0615 mm. The polyline distance is 0.096 mm +/ - 0.034 mm while the Hausdorff distance is 0.176 mm +/ - 0.047 mm. The algorithm compares favorably to both automatic and semiautomatic methods presented in the literature. | URI: | https://hdl.handle.net/20.500.14279/23596 | ISSN: | 15582531 | DOI: | 10.1109/TBME.2012.2214387 | Rights: | © IEEE | Type: | Article | Affiliation : | University of Cyprus Intercollege Cyprus Institute of Neurology and Genetics |
Publication Type: | Peer Reviewed |
Appears in Collections: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
57
checked on Feb 2, 2024
WEB OF SCIENCETM
Citations
50
Last Week
0
0
Last month
2
2
checked on Oct 29, 2023
Page view(s)
244
Last Week
0
0
Last month
2
2
checked on Nov 6, 2024
Google ScholarTM
Check
Altmetric
This item is licensed under a Creative Commons License