Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/23153
Τίτλος: Device-associated health care-associated infections: The effectiveness of a 3-year prevention and control program in the Republic of Cyprus
Συγγραφείς: Iordanou, Stelios 
Papathanassoglou, Elizabeth 
Middleton, Nicos 
Palazis, Lakis 
Timiliotou-Matsentidou, Chrystalla 
Raftopoulos, Vasilios 
Major Field of Science: Medical and Health Sciences
Field Category: Health Sciences
Λέξεις-κλειδιά: Catheter-associated urinary tract infection;Central line-associated bloodstream infection;Device associated infection;Health care-associated infection;Intensive care unit;Ventilator-associated pneumonia
Ημερομηνία Έκδοσης: 2020
Πηγή: Nursing in Critical Care, 2020
Περιοδικό: Nursing in Critical Care 
Περίληψη: Background: Device-associated health care-associated infections (DA-HAIs) are a major threat to patient safety, particularly in the Intensive Care Unit (ICU). This study aimed to evaluate the effectiveness of a bundle of infection control measures to reduce DA-HAIs in the ICU of a General Hospital in the Republic of Cyprus, over a 3-year period. Methods: We studied 599 ICU patients with a length of stay (LOS) for at least 48 hours. Our prospective cohort study was divided into three surveillance phases. Ventilator-associated pneumonia (VAP), central line-associated blood-stream infections (CLABSI), and catheter-associated blood-stream infections (CAUTI) incidence rates, LOS, and mortality were calculated before, during, and after the infection prevention and control programme. Results: There was a statistically significant reduction in the number of DA-HAI events during the surveillance periods, associated with DA-HAIs prevention efforts. In 2015 (prior to programme implementation), the baseline DA-HAIs instances were 43: 16 VAP (10.1/1000 Device Days), 21 (15.9/1000DD) CLABSIs, and 6 (2.66/1000DD) CAUTIs, (n = 198). During the second phase (2016), CLABSIs prevention measures were implemented and the number of infections were 24: 14 VAP (12.21/1000DD), 4 (4.2/1000DD) CLABSIs, and 6 (3.22/1000DD) CAUTIs, (n = 184). During the third phase (2017), VAP and CAUTI prevention measures were again implemented and the rates were 6: (3 VAP: 12.21/1000DD), 2 (1.95/1000DD) CLABSIs, and 1 (0.41/1000DD) CAUTIs, (n = 217). There was an overall reduction of 87% in the total number of DA-HAIs instances for the period 1 January 2015 to 31 December 2017. Conclusions: The significant overall reduction in DA-HAI rates indicates that a comprehensive infection control programme can affect DA-HAI rates.
URI: https://hdl.handle.net/20.500.14279/23153
ISSN: 14785153
DOI: 10.1111/nicc.12581
Rights: © Willey
Type: Article
Affiliation: Limassol General Hospital 
University of Alberta 
Cyprus University of Technology 
Nicosia General Hospital 
Hellenic National Public Health Organization 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

4
checked on 14 Μαρ 2024

WEB OF SCIENCETM
Citations

4
Last Week
0
Last month
1
checked on 29 Οκτ 2023

Page view(s)

256
Last Week
2
Last month
9
checked on 21 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons Creative Commons