Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/22768
Τίτλος: | Comparison of different cultures and culturing conditions for the biological deterioration of organic load from real saline bilge wastewater: microbial diversity insights and ecotoxicity assessment | Συγγραφείς: | Mazioti, Aikaterini A Vasquez Christodoulou, Marlen Vyrides, Ioannis |
Major Field of Science: | Natural Sciences | Field Category: | Chemical Sciences | Λέξεις-κλειδιά: | Aerobic treatment;Anaerobic granular sludge;Mixed bacterial cultures;Oily wastewater;Pseudodonghicola xiamenensis;Pure strains | Ημερομηνία Έκδοσης: | Ιου-2021 | Πηγή: | Environmental Science and Pollution Research, 2021, vol. 28, no. 27, pp. 36506 - 36522 | Volume: | 28 | Issue: | 27 | Start page: | 36506 | End page: | 36522 | Περιοδικό: | Environmental Science and Pollution Research | Περίληψη: | Bilge wastewater is a high strength, typically saline wastewater, originating from operation of ships. In this study, the treatment of real bilge wastewater was tested using pure isolated aerobic strains and mixed cultures (aerobic and anaerobic). The Chemical Oxygen Demand (COD) and ecotoxicity decrease were monitored over time, while the microbial dynamics alterations in mixed cultures were also recorded. The isolated strains Pseudodonghicola xiamenensis, Halomonas alkaliphila and Vibrio antiquaries were shown to significantly biodegrade bilge wastewater. Reasonable COD removal rates were achieved by aerobic mixed cultures (59%, 9 days), while anaerobic mixed cultures showed lower performance (34%, 51 days). The genus Pseudodonghicola was identified as dominant under aerobic conditions both in the mixed cultures and in the control sample (raw wastewater), after exposure to bilge wastewater, demonstrating natural proliferation of the genus and potential contribution to COD reduction. Biodegradation rates were higher when initial organic load was high, while the toxicity of raw wastewater partially decreased after treatment. | URI: | https://hdl.handle.net/20.500.14279/22768 | ISSN: | 16147499 | DOI: | 10.1007/s11356-021-13153-9 | Rights: | © The Author(s) | Type: | Article | Affiliation: | Cyprus University of Technology | Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
Mazioti2021_Article_ComparisonOfDifferentCulturesA.pdf | Fulltext | 1.46 MB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
5
checked on 2 Φεβ 2024
WEB OF SCIENCETM
Citations
5
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s) 50
325
Last Week
0
0
Last month
3
3
checked on 22 Δεκ 2024
Download(s)
406
checked on 22 Δεκ 2024
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons