Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/19265
Τίτλος: | Optimizing the energy storage schedule of a battery in a PV grid-connected nZEB using linear programming | Συγγραφείς: | Georgiou, Giorgos S. Christodoulides, Paul Kalogirou, Soteris A. |
Major Field of Science: | Engineering and Technology | Field Category: | Environmental Engineering | Λέξεις-κλειδιά: | Building energy optimization;Photovoltaics;Nearly zero energy buildings;Electrical energy storage;Linear programming;System advisor model | Ημερομηνία Έκδοσης: | 1-Οκτ-2020 | Πηγή: | Energy, 2020, vol. 208, articl. no. 118177 | Volume: | 208 | Περιοδικό: | Energy | Περίληψη: | Photovoltaic (PV) technology is highly adopted within buildings, as it is proven for reducing electricity bills. However, with the 2010/31/EU directive all new buildings shall be nearly Zero Energy Buildings (nZEB) from 2020 onward, with the requirement to maintain their energy consumption at low levels. For further embedding the nZEB concept in an integrated, holistic and efficient energy system, to overcome any application problems, one should not only focus on building energy efficiency designs, but also on smart and effective energy management techniques. For instance, as energy storage may contribute a key solution towards nZEB, a novel approach able to adapt to a given PV generation and load demand and individually control the battery and the net grid energy, is presented. This is achieved through Linear Programming (LP), a convex optimization tool, along with a weighted sum approach. Using real data, simulation results demonstrate that, choosing the right weight values based on the given generation and demand profiles, the LP model controls the building’s import energy, export energy and the battery accordingly. Hence, the net grid electrical energy is maintained to the minimum possible level. Finally, the LP model is crossed-checked with the freeware System Advisor Model (SAM) showing a normalized Root Mean Squared Error (nRMSE) of 2.10% for the annual battery dispatch. The analysis shows that the LP model combined with SAM, for addressing the non-linearity of the storage and to account for the power conversion losses, gives a lower annual net grid energy use than SAM’s automated target controller by 2.0%. | URI: | https://hdl.handle.net/20.500.14279/19265 | ISSN: | 03605442 | DOI: | 10.1016/j.energy.2020.118177 | Rights: | © Elsevier Attribution-NonCommercial-NoDerivatives 4.0 International |
Type: | Article | Affiliation: | Cyprus University of Technology Cyprus Academy of Science, Letters, and Arts |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
49
checked on 6 Νοε 2023
WEB OF SCIENCETM
Citations
40
Last Week
0
0
Last month
1
1
checked on 29 Οκτ 2023
Page view(s) 50
331
Last Week
5
5
Last month
12
12
checked on 11 Μαϊ 2024
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons