Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/19243
Τίτλος: Mitigation of coupled wind-wave-earthquake responses of a 10 MW fixed-bottom offshore wind turbine
Συγγραφείς: Yang, Yang 
Bashir, Musa 
Li, Chun 
Michailides, Constantine 
Wang, Jin 
Major Field of Science: Engineering and Technology
Field Category: Civil Engineering
Λέξεις-κλειδιά: Offshore wind turbines;Tuned mass dampers;Wind-wave-earthquake analysis;Structural control;Earthquake excitation
Ημερομηνία Έκδοσης: 1-Σεπ-2020
Πηγή: Renewable Energy, 2020 Vol. 157, pp. 1171-1184
Volume: 157
Start page: 1171
End page: 1184
Περιοδικό: Renewable Energy 
Περίληψη: In this paper we present a study on the mitigation of dynamic responses of a 10 MW monopile offshore wind turbine under coupled wind-wave-earthquake excitations. We have developed and validated the generic seismic coupled analysis and structural control architecture tool to overcome the limitation of numerical tools when examining the wind-wave-earthquake coupling effects. We investigated the dynamic responses of a 10 MW monopile offshore wind turbine under different loading combinations and found that the earthquake loading increases the tower-top displacement and pile-cap moment by 47.6% and 95.1%, respectively, compared to the wind-wave-only condition. It is found that the earthquake-induced vibration in the fore-aft direction is mitigated by the wind and wave loadings due to the energy dissipated by the aerodynamic and hydrodynamic damping. In addition, the tower responses are dominated by the earthquake excitation. In order to alleviate the tower vibration induced by the earthquake, we implemented the structural control capability within the tool using tuned mass dampers. The tuned mass dampers with appropriately selected design parameters achieve a larger mitigation on the tower-top displacement for the earthquake-only condition compared to the coupled-loading scenario. The reason is that the tuned mass damper is only effective in mitigating tower vibration, and it is not capable of reducing the tower elastic deformation which is the major contribution of the tower displacement for the coupled-loading condition. In addition, we have found that a heavier tuned mass damper requires a lower tuned frequency to achieve a larger mitigation. A configuration for the mitigation control of the 10 MW offshore wind turbine is suggested by using a 5% mass ratio of the tuned mass damper.
URI: https://hdl.handle.net/20.500.14279/19243
ISSN: 09601481
DOI: 10.1016/j.renene.2020.05.077
Rights: © 2020 Elsevier
Type: Article
Affiliation: Cyprus University of Technology 
University of Shanghai for Science and Technology 
Liverpool John Moores University 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations 20

46
checked on 14 Μαρ 2024

WEB OF SCIENCETM
Citations

30
Last Week
1
Last month
2
checked on 29 Οκτ 2023

Page view(s) 20

297
Last Week
1
Last month
8
checked on 30 Ιαν 2025

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα