Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/18271
Τίτλος: Evaluation of performance at experimental buildings and real demonstration sites in BFIRST project: Theoretical and practical aspects for BIPV monitoring system
Συγγραφείς: Pellegrino, Michele 
Matano, Arturo 
Flaminio, Giovanni 
Sanz, A. 
Roman, Eduardo 
Pierret, Stéphane 
Kyritsis, Anastasios 
Nikoletatos, John 
Tselepis, Stathis 
Mathas, E. 
Kalogirou, Soteris A. 
Major Field of Science: Engineering and Technology
Field Category: Environmental Engineering
Λέξεις-κλειδιά: Photovoltaic system performance monitoring;Building Integrated Photovoltaics
Ημερομηνία Έκδοσης: Μαρ-2017
Πηγή: First International Conference on Building Integrated Renewable Energy Systems, 2017, 6-9 March, Dublin, Ireland
Conference: International Conference on Building Integrated Renewable Energy Systems 
Περίληψη: Monitoring is one of the main activity of BFIRST, Building-integrated FIbre-Reinforced Solar Technology, project, a 5 years funded European project, project reference number 29601, that started in April 2102 and deals with the design, development and demonstration of a portfolio of innovative photovoltaic products for building integration, based on cell encapsulation within fibre-reinforced composite materials. Automatic data acquisition systems are generally required for monitoring, performance evaluation and exchanging data of PV systems. Standard IEC 61724:1998 “Photovoltaic system performance monitoring –Guidelines for measurement, data exchange and analysis” provides a guideline that shall be followed in these cases. As far as Building Integrated Photovoltaics (BIPV) are considered, besides electrical parameters there is in addition the need to monitor the specific building performances. That is because a BIPV module operates as a multi-functional building construction material; it generates energy and serves as part of the building envelope. Since the building related performances are not included in the aforementioned IEC standard, a general guideline for monitoring was prepared within the project that has been used within the project at two levels: one at experimental sites mainly related to experimental single module testing and the other at demosite with real PV size plants.
URI: https://hdl.handle.net/20.500.14279/18271
Type: Conference Papers
Affiliation: Italian Agency for New Technologies, Energy and Sustainable Economic Development 
Tecnalia Research and Innovation 
Optimal Computing 
Center for Renewable Energy Sources (CRES) 
Cyprus University of Technology 
Εμφανίζεται στις συλλογές:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
Kalogirou.pdfFulltext457.3 kBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

Page view(s) 50

273
Last Week
2
Last month
10
checked on 26 Μαϊ 2024

Download(s) 50

74
checked on 26 Μαϊ 2024

Google ScholarTM

Check


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα