Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/18078
Title: An improved method to estimate ultrasonic absorption in agar-based gel phantom using thermocouples and MR thermometry
Authors: Drakos, Theoharis 
Giannakou, Marinos 
Menikou, Georgios 
Ioannides, Cleanthis 
Damianou, Christakis A. 
Major Field of Science: Medical and Health Sciences
Field Category: Other Medical Sciences
Keywords: Absorption;Ultrasound;MRI;Agar;Silica
Issue Date: Apr-2020
Source: Ultrasonics, 2020, vol. 103, articl. no. 106089
Volume: 103
Journal: Ultrasonics 
Abstract: In this paper, a novel experimental set-up was developed that measures the absorption coefficient. The proposed system was evaluated in an agar-based gel phantom. The new experimental system provides accurate and fast measurement of the rate of temperature change within the phantom. The rate of temperature change was measured using thermocouple and was confirmed using MR thermometry. An ultrasonic transducer with a broad beam was used in order to reduce the conduction effect. The absorption coefficient of the agar-based phantom was 0.26 dB/cm-MHz using 4% agar, 30% evaporated milk and 4% silica. The absorption coefficient increased by increasing the volume of the evaporated milk, and agar. The absorption coefficient increased at low silica concentration (<4%) and then decreased at higher concentration of silica (>4%). By proper selection of evaporated milk, agar and silica concentration, it is possible to achieve similar coefficient like in soft tissues. Acoustic absorption measurement is considered as a difficult measurement in ultrasonics because obtaining the precise temperature change in the focus is challenging. Due to the quick and accurate placement of the thermocouple at the ultrasonic beam, it is possible with the proposed system to perform absorption measurement is less than one minute.
ISSN: 0041624X
DOI: 10.1016/j.ultras.2020.106089
Rights: © Elsevier
Type: Article
Affiliation : Ygia Polyclinic Hospital 
Cyprus University of Technology 
Nicosia General Hospital 
Publication Type: Peer Reviewed
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

SCOPUSTM   
Citations

14
checked on Feb 1, 2024

WEB OF SCIENCETM
Citations

12
Last Week
0
Last month
1
checked on Oct 29, 2023

Page view(s) 50

335
Last Week
0
Last month
5
checked on Dec 22, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.