Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/1531
Τίτλος: | Performance of solar systems employing collectors with colored absorber | Συγγραφείς: | Kalogirou, Soteris A. Tripanagnostopoulos, Yiannis Souliotis, Manolis |
Major Field of Science: | Engineering and Technology | Field Category: | Environmental Engineering | Λέξεις-κλειδιά: | Colored absorber;Solar collector;Water heating;Space heating;Industrial process heat | Ημερομηνία Έκδοσης: | Αυγ-2005 | Πηγή: | Energy and Buildings, 2005, Vol. 37, no. 8, pp. 824-835 | Volume: | 37 | Issue: | 8 | Start page: | 824 | End page: | 835 | Περιοδικό: | Energy and Buildings | Περίληψη: | Flat plate solar collectors are of black appearance because of the color of the absorber, which is employed to maximize the absorption of solar spectrum. Generally, to avoid the monotony of the black color we can use collectors with absorbers of blue, red–brown, green or other color. These collectors are of lower thermal efficiency than that of the usual black type collectors, because of the lower collector absorptance, but they are of more interest to architects for applications on traditional or modern buildings. In this paper, applications of solar collectors with colored absorbers in a large hot water system suitable for multi-flat residential or office buildings, a house heating system, and an industrial process heat system are presented. The collectors are analyzed with respect to their performance and practical applications, aiming to give guidelines for their wider use on buildings. These systems are simulated on an annual basis at three different locations at different latitudes, Nicosia, Cyprus (35°), Athens, Greece (38°) and Madison, Wisconsin (43°). All simulations are carried out with TRNSYS. The results show that although the colored collectors present lower efficiency than the typical black type collectors, the difference in energy output depends on the absorber darkness. For a medium value of the coefficient of absorptance (α = 0.85), the colored collectors give satisfactory results regarding the drop of the amount of collected energy for the three locations (about 7–18%), compared to collectors with black absorbers (α = 0.95). This implies the use of proportionate larger collector aperture area to have the same energy output as that of typical black colored collectors. Additionally, the economic figures obtained for the systems investigated are very promising. | URI: | https://hdl.handle.net/20.500.14279/1531 | ISSN: | 03787788 | DOI: | 10.1016/j.enbuild.2004.10.011 | Rights: | © Elsevier 2004 | Type: | Article | Affiliation: | Higher Technical Institute Cyprus University of Patras |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
39
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
31
Last Week
0
0
Last month
0
0
checked on 17 Οκτ 2023
Page view(s)
479
Last Week
1
1
Last month
0
0
checked on 21 Νοε 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα