Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/14052
Τίτλος: | Nanometer-sized ceria-coated silica-iron oxide for the reagentless microextraction/preconcentration of heavy metals in environmental and biological samples followed by slurry introduction to ICP-OES | Συγγραφείς: | Dados, A Paparizou, E Eleftheriou, Polyvios Papastephanou, C Stalikas, C D |
Major Field of Science: | Engineering and Technology | Field Category: | Mechanical Engineering | Λέξεις-κλειδιά: | Heavy metals microextraction/preconcentration; Inductively coupled plasma-optical emission spectrometry; Nanometer-sized magnetic ceria; Slurry suspension sampling;Inductively coupled plasma-optical emission spectrometry;Nanometer-sized magnetic ceria;Slurry suspension sampling | Ημερομηνία Έκδοσης: | Απρ-2014 | Πηγή: | Talanta,2014, vol. 121, App. 127-135 | Volume: | 121 | Start page: | 127 | End page: | 135 | Περιοδικό: | Talanta | Περίληψη: | A slurry suspension sampling technique is developed and optimized for the rapid microextraction of heavy metals and analysis using nanometer-sized ceria-coated silica-iron oxide particles and inductively coupled plasma optical emission spectrometry (ICP-OES). Magnetic-silica material is synthesized by a co-precipitation and sol-gel method followed by ceria coating through a precipitation. The large particles are removed using a sedimentation-fractionation procedure and a magnetic homogeneous colloidal suspension of ceria-modified iron oxide-silica is produced for microextraction. The nanometer-sized particles are separated from the sample solution magnetically and analyzed with ICP-OES using a slurry suspension sampling approach. The ceria-modified iron oxide-silica does not contain any organic matter and this probably justifies the absence of matrix effect on plasma atomization capacity, when increased concentrations of slurries are aspirated. The As, Be, Mo, Cr, Cu, Pb, Hg, Sb, Se and V can be preconcentrated by the proposed method at pH 6.0 while Mn, Cd, Co and Ni require a pH ≥ 8.0. Satisfactory values are obtained for the relative standard deviations (2-6%), recoveries (88-102%), enrichment factors (14-19) and regression correlation coefficients as well as detectability, at sub-μg L(-1) levels. The applicability of magnetic ceria for the microextraction of metal ions in combination with the slurry introduction technique using ICP is substantiated by the analysis of environmental water and urine samples. | ISSN: | 18733573 | DOI: | 10.1016/j.talanta.2013.12.045 | Rights: | © Elsevier | Type: | Article | Affiliation: | Cyprus University of Technology University of Ioannina Cp Foodlab Ltd. |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
36
checked on 1 Φεβ 2024
WEB OF SCIENCETM
Citations
35
Last Week
1
1
Last month
1
1
checked on 29 Οκτ 2023
Page view(s)
337
Last Week
0
0
Last month
30
30
checked on 14 Μαρ 2025
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα