Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/1397
Title: Intramachine and intermachine variability in transesophageal color doppler images of pulsatile jets: in vitro studies
Authors: Fan, Pohoey 
Nanda, Navin C. 
Anayiotos, Andreas 
metadata.dc.contributor.other: Αναγιωτός, Ανδρέας
Major Field of Science: Social Sciences
Keywords: Echocardiography;Diagnostic imaging;Image analysis;Transesophageal echocardiography;Algorithms
Issue Date: May-1994
Source: Circulation research, 1994, vol. 89, no. 5, pp. 2141-2149
Volume: 89
Issue: 5
Start page: 2141
End page: 2149
Journal: Circulation research 
Abstract: Background: Color Doppler flow mapping is widely used as a marker of severity of valvular regurgitation, and the transesophageal approach has provided high-quality images in patients with poor acoustic windows. However, different instruments produce significantly variable images. Techniques that use jet spatial information to determine the severity of the lesion may need to be derived specifically for the instrument used. Given a lack of standardization of the many commonly used instruments, the goal of this study was to quantify variability between instruments by imaging well-defined jet flow fields created in vitro. Methods and Results: Pulsatile jets were created in vitro using a blood analogue fluid through physiological orifice diameters and imaged from a distal window using six commonly used color Doppler instruments. Transesophageal transducers (5.0 MHz) were used with all instruments studied. Peak jet areas were planimetered and averaged with systematic variations in Nyquist limit, color filter, and sector angle (which produced variations in frame rate). Changes in instrument settings produced significant variation in jet size for all instruments studied. Comparisons within instruments and among instruments were difficult because of preset and ambiguous setting levels. When comparisons were possible between similar settings, variability was dramatic (eg, 57% variability between instruments with very similar Nyquist limits). Conclusions: A lack of standardized color Doppler instrument settings prohibits translation of jet area techniques from one instrument to another. This should be taken into consideration when using different machines for clinical study.
URI: https://hdl.handle.net/20.500.14279/1397
ISSN: 00097322
DOI: 10.1161/01.CIR.89.5.2141
Rights: © Lippincott Williams and Wilkins
Type: Article
Affiliation: University of Alabama at Birmingham 
Affiliation : University of Alabama 
Georgia Institute of Technology 
University of Pittsburgh 
University of Alabama at Birmingham 
Publication Type: Peer Reviewed
Appears in Collections:Άρθρα/Articles

Files in This Item:
File Description SizeFormat
intramachine and intermachine variability.pdf1.86 MBAdobe PDFView/Open
CORE Recommender
Show full item record

SCOPUSTM   
Citations

13
checked on Nov 9, 2023

WEB OF SCIENCETM
Citations 50

11
Last Week
0
Last month
0
checked on Oct 29, 2023

Page view(s)

522
Last Week
0
Last month
2
checked on Nov 21, 2024

Download(s)

336
checked on Nov 21, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.