Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/13886
Τίτλος: Taking advantage of near-field heating in order to increase ablated volume during high intensity focused ultrasound
Συγγραφείς: Damianou, Christakis A. 
Komodromos, M. 
Koupis, A. 
Curiel, Laura 
Chapelon, Jean Yves 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Λέξεις-κλειδιά: Ablation volume;IFU;Near-field heating
Ημερομηνία Έκδοσης: 8-Μαΐ-2006
Πηγή: 5th International Symposium on Therapeutic Ultrasound; Boston, MA; United States; 27 October 2005 through 29 October 2005
Volume: 829
Conference: International Symposium on Therapeutic Ultrasound 
Περίληψη: The goal of the study was to suggest ultrasonic parameters that take advantage of near-field heating in order to increase the volume of the ablated tissue and consequently reducing the total time of high intensity ultrasonic ablation. The main parameter evaluated as an indicator of producing controlled lesions was the ratio of width of necrosis at the focal region over the width of necrosis in the near-field (WI/WN). A W I/WN close to 1 indicated a good reflection of the focal heating, meaning that the lesion was controlled and could be used to increase the ablated volume. The most significant ultrasonic parameter that reduced the treatment time was the delay between successive ultrasonic firings. It was found that at a spatial in situ intensity close to 1000 W/cm2, the W I/WN is close to 1 even with a delay between successive ultrasonic firings as low as 10 s (transducer T1: 50 mm diameter, 40 mm radius of curvature, and frequency of 3 MHz). The lower the intensity or the higher the delay, the closer to unity is WI/WN. For a different transducer (T2: 40 mm diameter, 40 mm radius of curvature, and frequency of 3 MHz) the WI/WN was lower, indicating that the transducer geometry can play an important role for producing controlled lesions in the near-field. However, the same concepts were also observed for both geometries. This technique of increasing the ablated volume was verified in turkey tissue in vitro. The effect of other parameters such as frequency, focal depth and area of the grid pattern on is still under investigation. © 2006 American Institute of Physics.
Description: Part of AIP Conference Proceedings Volume 829
ISBN: 978-073540321-5
ISSN: 0094243X
DOI: 10.1063/1.2205451
Rights: © AIP Publishing
Type: Conference Papers
Affiliation: INSERM 
Frederick University 
Εμφανίζεται στις συλλογές:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

Page view(s) 10

235
Last Week
1
Last month
13
checked on 17 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα