Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/13866
Τίτλος: | The usefulness of a contrast agent and gradient-recalled acquisition in a steady-state imaging sequence for magnetic resonance imaging-guided noninvasive ultrasound surgery | Συγγραφείς: | Schenck, John F. Hynynen, Kullervo Unger, Evan Darkazanli, Ammar Damianou, Christakis A. |
Major Field of Science: | Engineering and Technology | Field Category: | Electrical Engineering - Electronic Engineering - Information Engineering | Λέξεις-κλειδιά: | Contrast agent;Magnetic resonance imaging;Surgery;Ultrasound | Ημερομηνία Έκδοσης: | 1-Ιαν-1994 | Πηγή: | Investigative Radiology, 1994, vol. 29, no. 10, pp. 897-903 | Volume: | 29 | Issue: | 10 | Start page: | 897 | End page: | 903 | Περιοδικό: | Investigative Radiology | Περίληψη: | Rationale and Objectives. The ability of magnetic resonance imaging to detect small temperature elevations from focused ultrasound surgery beams was studied. In addition, the value of a contrast agent in delineating the necrosed tissue volume was investigated. materials and methods. Gradient-recalled acquisition in a steady state (GRASS) T1-weighted images were used to follow the temperature elevation and tissue changes during 2-minute sonications in the thigh muscles of 10 rabbits. The effects of the treatment on the vascular network was investigated by injecting a contrast agent bolus before or after the son-ication. Results. The signal intensity decreased during the sonica-tion, and the reduction was directly proportional to the applied power and increase in temperature. The signal intensity returned gradually back to baseline after the ultrasound was turned off. Injection of the contrast agent increased the signal intensity in muscle, but not in the necrosed tissue. The dimensions of the delineated tissue volume were the same as mca-sured from the T2-weightcd fast-spin-echo images and postmortem tissue examination. Conclusions. These results indicate that magnetic resonance imaging can be used to detect temperature elevations that do not cause tissue damage and that contrast agent can be used to delineate the necrosed tissue volume. © 1994. J.B. Lippincott Company. | ISSN: | 00209996 | DOI: | 10.1097/00004424-199410000-00006 | Rights: | © Wolters Kluwer | Type: | Article | Affiliation: | University of Arizona General Electric Company Harvard University |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
8
checked on 1 Φεβ 2024
WEB OF SCIENCETM
Citations
60
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s) 50
287
Last Week
1
1
Last month
11
11
checked on 11 Μαϊ 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα