Τίτλος: The usefulness of a contrast agent and gradient-recalled acquisition in a steady-state imaging sequence for magnetic resonance imaging-guided noninvasive ultrasound surgery
Συγγραφείς: Schenck, John F. 
Hynynen, Kullervo 
Unger, Evan 
Darkazanli, Ammar 
Damianou, Christakis A. 
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Λέξεις-κλειδιά: Contrast agent;Magnetic resonance imaging;Surgery;Ultrasound
Ημερομηνία Έκδοσης: 1-Ιαν-1994
Πηγή: Investigative Radiology, 1994, vol. 29, no. 10, pp. 897-903
Volume: 29
Issue: 10
Start page: 897
End page: 903
Περιοδικό: Investigative Radiology 
Περίληψη: Rationale and Objectives. The ability of magnetic resonance imaging to detect small temperature elevations from focused ultrasound surgery beams was studied. In addition, the value of a contrast agent in delineating the necrosed tissue volume was investigated. materials and methods. Gradient-recalled acquisition in a steady state (GRASS) T1-weighted images were used to follow the temperature elevation and tissue changes during 2-minute sonications in the thigh muscles of 10 rabbits. The effects of the treatment on the vascular network was investigated by injecting a contrast agent bolus before or after the son-ication. Results. The signal intensity decreased during the sonica-tion, and the reduction was directly proportional to the applied power and increase in temperature. The signal intensity returned gradually back to baseline after the ultrasound was turned off. Injection of the contrast agent increased the signal intensity in muscle, but not in the necrosed tissue. The dimensions of the delineated tissue volume were the same as mca-sured from the T2-weightcd fast-spin-echo images and postmortem tissue examination. Conclusions. These results indicate that magnetic resonance imaging can be used to detect temperature elevations that do not cause tissue damage and that contrast agent can be used to delineate the necrosed tissue volume. © 1994. J.B. Lippincott Company.
ISSN: 00209996
DOI: 10.1097/00004424-199410000-00006
Rights: © Wolters Kluwer
Type: Article
Affiliation: University of Arizona 
General Electric Company 
Harvard University 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

8
checked on 1 Φεβ 2024

WEB OF SCIENCETM
Citations

60
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s) 50

287
Last Week
1
Last month
11
checked on 11 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα