dc.identifier.citationUltrasound in Medicine and Biology, 1995, vol. 21, no. 7, pp. 969-979en_US
dc.identifier.issn03015629-
dc.description.abstractIn this study, the threshold for subharmonic emission during in vivo sonication of rabbit brain was investigated. In addition, the histologic effects of pulsed sonication above this threshold were studied. Two spherically curved focused ultrasound transducers with a diameter of 80 mm and a radius of curvature of 70 mm were used in the sonications. The operating frequencies of the transducers were 0.936 and 1.72 MHz. The sonication duration was varied between 0.001 and 1 s and the repetition frequency between 0.1 and 5 Hz. The threshold for subharmonic emission at the frequency of 0.936 MHz was found to be approximately 2000 W cm-2 and 3600 W cm-2 for pulse durations of 1 s and 0.001 s, respectively. The threshold was approximately 1.5-fold as high at a frequency of 1.72 MHz. However, there was considerable variation from experiment to experiment. The multiple pulse experiments at a frequency of 1.72 MHz and an intensity of 7000 W cm-2 showed that the histologic effects ranged from no observable damage of the tissue, to blood-brain barrier breakage, to local haemorrhagia, to local destruction of the tissue, to gross hemorrhage resulting in the death of the animal. The severity of the tissue damage increased as the pulse duration, number of pulses and their repetition frequency increased. The results indicate that the end point of the tissue damage may be controlled by selecting the sonication parameters. Such control over tissue effects can have several different applications when brain disorders are treated. © 1995.en_US
dc.formatpdfen_US
dc.language.isoenen_US
dc.relation.ispartofUltrasound in Medicine and Biologyen_US
dc.rights© Elsevieren_US
dc.subjectBioeffectsen_US
dc.subjectCavitationen_US
dc.subjectMinimally invasive surgeryen_US
dc.subjectUltrasounden_US
dc.titleHistologic effects of high intensity pulsed ultrasound exposure with subharmonic emission in rabbit brain in vivoen_US
dc.typeArticleen_US
dc.collaborationRussian Academy of Medical Sciencesen_US
dc.collaborationUniversity of Arizona Health Sciences Centeren_US
dc.subject.categoryElectrical Engineering - Electronic Engineering - Information Engineeringen_US
dc.countryUnited Statesen_US
dc.countryRussiaen_US
dc.subject.fieldEngineering and Technologyen_US
dc.publicationPeer Revieweden_US
dc.identifier.doi10.1016/0301-5629(95)00038-Sen_US
dc.identifier.pmid21en
dc.identifier.scopus2-s2.0-0029148503en
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/0029148503en
dc.contributor.orcid#NODATA#en
dc.contributor.orcid#NODATA#en
dc.contributor.orcid#NODATA#en
dc.relation.issue7en_US
dc.relation.volume21en_US
cut.common.academicyear2019-2020en_US
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.openairetypearticle-
item.languageiso639-1en-
crisitem.journal.journalissn0301-5629-
crisitem.journal.publisherElsevier-
crisitem.author.deptDepartment of Electrical Engineering, Computer Engineering and Informatics-
crisitem.author.facultyFaculty of Engineering and Technology-
crisitem.author.orcid0000-0003-0424-2851-
crisitem.author.parentorgFaculty of Engineering and Technology-
Appears in Collections:Άρθρα/Articles
CORE Recommender
Show simple item record

SCOPUSTM   
Citations

27
checked on Feb 1, 2024

WEB OF SCIENCETM
Citations

165
Last Week
0
Last month
0
checked on Oct 29, 2023

Page view(s)

277
Last Week
4
Last month
11
checked on May 13, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.