Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/1340
Τίτλος: Performance enhancement of an integrated collector storage hot water system
Συγγραφείς: Kalogirou, Soteris A. 
Major Field of Science: Engineering and Technology
Field Category: Materials Engineering
Λέξεις-κλειδιά: Integrated Collector Storage (ICS) system;Hot water production;Convection suppression
Ημερομηνία Έκδοσης: Απρ-1999
Πηγή: Renewable Energy,1999, vol. 16, no. 1-4, pp. 652-655
Volume: 16
Issue: 1-4
Start page: 652
End page: 655
Περιοδικό: Renewable Energy 
Περίληψη: Integrated collector storage (ICS) systems offer a solution to reduce the height of the conventional flat-plate thermosiphon type collectors. The initial system developed had an aperture area of 1.77 m2, a receiver diameter of 200 mm, a concentration ratio of 1.47 and total water storage volume of 65 litres. The main disadvantage of the ICS systems comes from their design, i.e., because the collector absorber is also the storage cylinder it is not possible to insulate it properly and therefore there are significant losses during the night. The main cause of these losses is the convection currents created during the night, circulating around the top glass cover. Another disadvantage of the system is its draw-off characteristics. Because the water cylinder/absorber is horizontal there is very little stratification of the water in the cylinder. It is suggested that a primary 110 mm diameter cylinder is introduced at the space between the main cylinder and the glass. The cold water is introduced directly to the primary cylinder, which feeds the main cylinder. With this modification the convection currents are drastically reduced due to the obstruction created by the primary vessel, thus reducing the night thermal losses. Also as the cold water is introduced first to the primary cylinder there is no direct mixing of the two streams thus greatly improving the system draw-off characteristics. This modification creates an 8% increase in the total cost of the system, which is reasonable, if the above benefits are considered.
Description: Presented at World Renewable Energy Congress, 1998, 20-25 September, Florence, Italy
URI: https://hdl.handle.net/20.500.14279/1340
ISSN: 09601481
DOI: 10.1016/S0960-1481(98)00245-6
Rights: © Elsevier
Type: Article
Affiliation: Higher Technical Institute Cyprus 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

27
checked on 21 Μαρ 2021

WEB OF SCIENCETM
Citations

25
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s)

504
Last Week
1
Last month
7
checked on 30 Ιαν 2025

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα