Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/1133
Τίτλος: Novel colorimetric method overcoming phosphorus interference during trace arsenic analysis in soil solution
Συγγραφείς: Punamiya, Pravin 
Sarkar, Dibyendu 
Datta, Rupali K. 
Makris, Konstantinos C. 
Major Field of Science: Natural Sciences
Field Category: Earth and Related Environmental Sciences
Λέξεις-κλειδιά: Aluminum;Arsenic;Ascorbic acid;Chromium;Copper;Iron;Lead;Malachite green;Nickel;Phosphorus;Silicon;Soil water;Zinc
Ημερομηνία Έκδοσης: 2008
Πηγή: Analyst, 2008, vol. 133, iss. 2, pp. 191-196
Volume: 133
Issue: 2
Start page: 191
End page: 196
Περιοδικό: Analyst 
Περίληψη: A sensitive (method detection limit, 2.0 μg As L-1) colorimetric determination of trace As(v) and As(iii) concentrations in the presence of soluble phosphorus (P) concentrations in soil/water extracts is presented. The proposed method modifies the malachite green method (MG) originally developed for P in soil and water. Our method relies upon the finding that As(iii) and As(v) do not develop the green color during P analysis using the MG method. When an optimum concentration of ascorbic acid (AA) is added to a sample containing up to 15 times P > As (μM) concentrations, the final sample absorbance due to P will be equal to that of As(v) molecules. The soluble As concentration can then be quantified by the concentration difference between the mixed oxyanion (As + P) absorbance (proposed method) and the MG method absorbance that measures only P. Our method is miniaturized using a 96-well microplate UV-VIS reader that utilizes minute reagent and sample volumes (120 and 200 μL sample-1, respectively), thus, minimizing waste and offering flexibility in the field. Our method was tested in a suite of As-contaminated soils that successfully measured both As and P in soil water extracts and total digests. Mean% As recoveries ranged between 84 and 117%, corroborating data obtained with high-resolution inductively-coupled plasma mass-spectrometry. The performance of the proposed colorimetric As method was unaffected by the presence of Cu, Zn, Pb, Ni, Fe, Al, Si, and Cr in both neutral and highly-acidic (ca. pH 2) soil extracts. Data from this study provide the proof of concept towards creating a field-deployable, portable As kit.
URI: https://hdl.handle.net/20.500.14279/1133
ISSN: 32654
DOI: 10.1039/B714389C
Rights: © The Royal Society of Chemistry
Type: Article
Affiliation: University of Texas 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

8
checked on 21 Μαρ 2021

WEB OF SCIENCETM
Citations 50

8
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s)

476
Last Week
0
Last month
11
checked on 12 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα