Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/11013
Τίτλος: | Building-façade integrated solar thermal collectors: Energy-economic performance and indoor comfort simulation model of a water based prototype for heating, cooling, and DHW production | Συγγραφείς: | Buonomano, Annamaria Forzano, Cesare Kalogirou, Soteris A. Palombo, Adolfo |
Major Field of Science: | Engineering and Technology | Field Category: | Materials Engineering | Λέξεις-κλειδιά: | Building integrated solar thermal systems;Dynamic energy performance analysis;Experimental validation;Low cost materials | Ημερομηνία Έκδοσης: | Ιου-2019 | Πηγή: | Renewable Energy, 2019, vol. 137, pp. 20-36 | Volume: | 137 | Start page: | 20 | End page: | 36 | Περιοδικό: | Renewable Energy | Περίληψη: | This paper presents the design and the thermodynamic analysis of a new prototype of flat-plate solar thermal collector, suitable for building integration, using water as working fluid. The main novelty of the proposed solar thermal collector is the use of cheap materials and simple design solutions, taken into account with the aim to reduce the manufacturing and installation costs towards the improvement of the market penetration of this technology in the near-term future. The collector is suitable for domestic hot water production and for space heating and cooling, achieved through the use of adsorption chillers. A suitable dynamic simulation model for the system energy, comfort, economic, and environmental performance assessment is developed by taking into account both active and passive effects related to the building integration of the solar collector. The developed simulation model, implemented in a suitable MatLab computer tool, is experimentally validated; the main results of the validation process are discussed in this paper. Moreover, in order to show the potential of the presented building integrated collector prototype and of the related simulation tool, a suitable case study is developed. It refers to a residential unit of a multi-floor building where the prototype collectors are integrated on the South façade. Simulations are carried out for 2 building envelope weights and 9 different weather zones. Interesting outcomes from the energy, economic, environmental, and comfort point of views are obtained. | URI: | https://hdl.handle.net/20.500.14279/11013 | ISSN: | 09601481 | DOI: | 10.1016/j.renene.2018.01.059 | Rights: | © Elsevier | Type: | Article | Affiliation: | University of Naples Federico Piazza Università 5 Cyprus University of Technology |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
55
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
44
Last Week
0
0
Last month
0
0
checked on 17 Αυγ 2023
Page view(s)
466
Last Week
0
0
Last month
5
5
checked on 23 Νοε 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα