Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.14279/1087
Title: First-trimester Ductus Venosus Screening for Cardiac Defects: a Meta-analysis
Authors: Papatheodorou, Stefania 
Makrydimas, George V. 
Ioannidis, John P. A. 
Evangelou, Evangelos 
metadata.dc.contributor.other: Παπαθεοδώρου, Στεφανία
Ευαγγέλου, Ευάγγελος
Μακρυδήμας, Γεώργιος
Ιωαννίδης, Ιωάνννης Π. Α.
Major Field of Science: Medical and Health Sciences
Field Category: Clinical Medicine
Keywords: Chromosome aberration;Congenital heart malformation;Diagnostic accuracy;Ductus venosus;Echography;First trimester pregnancy;Karyotype;Nuchal translucency measurement
Issue Date: Mar-2012
Source: Obstetrical & Gynecological Survey, 2012, vol.67, no.3, pp.148–149
Volume: 67
Issue: 3
Start page: 148
End page: 149
Link: http://journals.lww.com/obgynsurvey/Abstract/2012/03000/First_Trimester_Ductus_Venosus_Screening_for.7.aspx
Journal: Obstetrical & Gynecological Survey 
Abstract: Cardiac defects, the most common form of congenital anomaly, are found in 2–8 of every 1000 pregnancies. Increased nuchal translucency (NT) on ultrasound is an established marker for first-trimester detection of congenital heart defects (CHDs), with or without structural anomalies, in chromosomally normal and abnormal fetuses. However, due to modest sensitivity and specificity, many fetuses with increased NT who do not have CHD may undergo detailed cardiac scans. Moreover, NT screening may miss some fetuses with CHD and normal karyotype. Ductus venosus (DV) Doppler waveform has been investigated to improve the diagnostic discrimination of ultrasound among cardiac anomalies in chromosomally abnormal and normal fetuses. DV has shown variable results in several studies in fetuses with normal karyotype; its value for identifying fetuses with CHD in the setting of a normal versus an increased NT is unclear. The aim of this meta-analysis was to evaluate the diagnostic performance of first-trimester DV for detection of CHD in chromosomally normal fetuses. A search of MEDLINE, ISI, SCOPUS, and EMBASE was performed for studies published between 1999 and 2011. Key words included “ductus venosus,” “DV,” “chromosomal abnormalities,” “congenital heart disease,” and “nuchal translucency.” The diagnostic accuracy of DV was examined in 7 studies involving 50,354 fetuses with normal karyotype regardless of NT status, 9 studies including 2908 fetuses with increased NT, and 7 studies involving 47,610 fetuses with normal NT. Hierarchical summary receiver operating characteristic curves were drawn based on parameters of the fitted models. Analysis of the hierarchical summary receiver operating characteristic curves showed that the sensitivity and specificity of DV to detect CHD in the normal karyotype population regardless of the NT status were 0.50 and 0.93, respectively. Summary sensitivity and specificity were 83% and 80% among participants with increased NT, and 19% and 96% among those with normal NT, respectively. The findings of this meta-analysis showing the estimated performance of DV for detecting CHD in chromosomally normal fetuses should be considered in evaluating the potential use of this screening test and its limitations.
URI: https://hdl.handle.net/20.500.14279/1087
ISSN: 15339866
Rights: © Lippincott Williams & Wilkins
Attribution-NonCommercial-NoDerivs 3.0 United States
Type: Article
Affiliation : University of Ioannina 
Stanford University 
Publication Type: Peer Reviewed
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

Page view(s) 20

471
Last Week
2
Last month
3
checked on Nov 22, 2024

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons