Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.14279/10506
Title: | Computer aided detection in prostate cancer diagnostics: A promising alternative to biopsy? A retrospective study from 104 lesions with histological ground truth | Authors: | Thon, Anika Teichgräber, Ulf Tennstedt-Schenk, Cornelia Hadjidemetriou, Stathis Winzler, Sven Malich, Ansgar Papageorgiou, Ismini |
Major Field of Science: | Engineering and Technology | Field Category: | Other Engineering and Technologies | Keywords: | Multiparametric magnetic resonance imaging (mpMRI);Radiotherapy;Localization;B-Value | Issue Date: | Oct-2017 | Source: | PLoS ONE, 2017, vol. 12, no. 10 | Volume: | 12 | Issue: | 10 | Journal: | PLoS ONE | Abstract: | Prostate cancer (PCa) diagnosis by means of multiparametric magnetic resonance imaging (mpMRI) is a current challenge for the development of computer-aided detection (CAD) tools. An innovative CAD-software (Watson Elementary (TM)) was proposed to achieve high sensitivity and specificity, as well as to allege a correlate to Gleason grade. Aim/Objective To assess the performance of Watson Elementary (TM) in automated PCa diagnosis in our hospital's database of MRI-guided prostate biopsies. Methods The evaluation was retrospective for 104 lesions (47 PCa, 57 benign) from 79, 64.61 +/- 6.64 year old patients using 3T T2-weighted imaging, Apparent Diffusion Coefficient (ADC) maps and dynamic contrast enhancement series. Watson Elementary (TM) utilizes signal intensity, diffusion properties and kinetic profile to compute a proportional Gleason grade predictor, termed Malignancy Attention Index (MAI). The analysis focused on (i) the CAD sensitivity and specificity to classify suspect lesions and (ii) the MAI correlation with the histopathological ground truth. Results The software revealed a sensitivity of 46.80% for PCa classification. The specificity for PCa was found to be 75.43% with a positive predictive value of 61.11%, a negative predictive value of 63.23% and a false discovery rate of 38.89%. CAD classified PCa and benign lesions with equal probability (P 0.06,chi(2) test). Accordingly, receiver operating characteristic analysis suggests a poor predictive value for MAI with an area under curve of 0.65 (P 0.02), which is not superior to the performance of board certified observers. Moreover, MAI revealed no significant correlation with Gleason grade (P 0.60, Pearson's correlation). Conclusion The tested CAD software for mpMRI analysis was a weak PCa biomarker in this dataset. Targeted prostate biopsy and histology remains the gold standard for prostate cancer diagnosis. | URI: | https://hdl.handle.net/20.500.14279/10506 | ISSN: | 19326203 | DOI: | 10.1371/journal.pone.0185995 | Rights: | © Thon et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. | Type: | Article | Affiliation : | Cyprus University of Technology Friedrich Schiller University of Jena Suedharz Hospital Nordhausen University of Bern |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
Hadjidemetriou.pdf | 12.03 MB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
19
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
50
17
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s) 50
391
Last Week
0
0
Last month
7
7
checked on 22 Δεκ 2024
Download(s)
106
checked on 22 Δεκ 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα