Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/10065
Τίτλος: | MRI-guided coupling for a focused ultrasound system using a top-to-bottom propagation | Συγγραφείς: | Yiannakou, Marinos Menikou, Georgios Yiallouras, Christos Damianou, Christakis A. |
Major Field of Science: | Engineering and Technology | Field Category: | Mechanical Engineering | Λέξεις-κλειδιά: | Cancer;Fibroid;MRI;Robot;Ultrasound | Ημερομηνία Έκδοσης: | 23-Ιαν-2017 | Πηγή: | Journal of Therapeutic Ultrasound, 2017, vol. 5, no. 1 | Volume: | 5 | Issue: | 1 | Περιοδικό: | Journal of Therapeutic Ultrasound | Περίληψη: | Background: A novel magnetic resonance imaging (MRI)-conditional coupling system was developed that accommodates a focused ultrasound (FUS) transducer. With this coupling system, the transducer can access targets from top to bottom. The intended clinical application is treatment of fibroids using FUS with the patient placed in supine position. Methods: The coupling system was manufactured using a rapid prototyping device using acrylonitrile butadiene styrene (ABS) plastic. Coupling to a gel phantom was achieved using a water bag filled with degassed water. The FUS transducer was immersed in the water bag. Results: The coupling system was successfully tested for MRI compatibility using fast-gradient pulse sequences in a gel phantom. The robotic system with its new coupling system was evaluated for its functionality for creating discrete and multiple (overlapping) lesions in the gel phantom. Conclusions: An MRI-conditional FUS coupling system integrated with an existing robotic system was developed that has the potential to create thermal lesions in targets using a top-to-bottom approach. This system has the potential to treat fibroid tumors with the patient lying in supine position. | URI: | https://hdl.handle.net/20.500.14279/10065 | ISSN: | 20505736 | DOI: | 10.1186/s40349-017-0087-x | Rights: | © The Author(s). This article is distributed under the terms of the Creative Commons Attribution 4.0 International License , which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver applies to the data made available in this article, unless otherwise stated | Type: | Article | Affiliation: | Cyprus University of Technology City University London Medsonic Ltd |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
Yiannakou, Yiallouras and Damianou.pdf | 2.1 MB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
6
checked on 9 Νοε 2023
Page view(s)
422
Last Week
1
1
Last month
1
1
checked on 29 Ιαν 2025
Download(s) 20
153
checked on 29 Ιαν 2025
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα