Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/9746
Τίτλος: Behavior of unreinforced masonry prisms and beams retrofitted with engineered cementitious composites
Συγγραφείς: Kyriakides, Marios 
Billington, Sarah L. 
Major Field of Science: Engineering and Technology
Field Category: Civil Engineering
Λέξεις-κλειδιά: Compression tests;Engineered cementitious composites;Flexural tests;Retrofit;Sprayable;Unreinforced masonry
Ημερομηνία Έκδοσης: Σεπ-2014
Πηγή: Materials and Structures/Materiaux et Constructions, 2014, vol. 47, no. 9, pp. 1573-1587
Volume: 47
Issue: 9
Start page: 1573
End page: 1587
Περιοδικό: Materials and Structures/Materiaux et Constructions, 
Περίληψη: The impact of a thin layer of a ductile fiber-reinforced concrete referred to as engineered cementitious composites (ECC) on unreinforced masonry (URM) prisms and beams has been evaluated. The objective of the research was to characterize the performance and potential benefits of using ECC to retrofit URM with eventual application to masonry infill walls in non-ductile reinforced concrete frames. Compression tests of masonry prisms and flexural tests of masonry beams with different ECC retrofit schemes were conducted. The variables studied were the use of wall anchors to improve the ECC-masonry bond and alternate steel reinforcement ratios within the ECC layer in the form of welded wire fabric. The ECC retrofit was found to increase the strength and stiffness of URM prisms by 45 and 53 %, respectively compared to those of a plain specimen. When wall anchors were installed on the masonry specimens, the bond between the ECC layer and the masonry surface was improved. Four-point bending tests indicated that the strength and more importantly the ductility of an ECC retrofitted brick beam are increased significantly, especially when light reinforcement is added to the ECC layer, relative to an URM beam. Analytical models for estimating the strength and stiffness of ECC retrofitted masonry specimens are proposed and evaluated.
URI: https://hdl.handle.net/20.500.14279/9746
ISSN: 13595997
DOI: 10.1617/s11527-013-0138-x
Rights: © RILEM
Type: Article
Affiliation: Cyprus University of Technology 
Stanford University 
Publication Type: Peer Reviewed
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

19
checked on 6 Νοε 2023

WEB OF SCIENCETM
Citations 50

14
Last Week
1
Last month
0
checked on 29 Οκτ 2023

Page view(s)

449
Last Week
1
Last month
2
checked on 21 Νοε 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα