Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/9746
Τίτλος: | Behavior of unreinforced masonry prisms and beams retrofitted with engineered cementitious composites | Συγγραφείς: | Kyriakides, Marios Billington, Sarah L. |
Major Field of Science: | Engineering and Technology | Field Category: | Civil Engineering | Λέξεις-κλειδιά: | Compression tests;Engineered cementitious composites;Flexural tests;Retrofit;Sprayable;Unreinforced masonry | Ημερομηνία Έκδοσης: | Σεπ-2014 | Πηγή: | Materials and Structures/Materiaux et Constructions, 2014, vol. 47, no. 9, pp. 1573-1587 | Volume: | 47 | Issue: | 9 | Start page: | 1573 | End page: | 1587 | Περιοδικό: | Materials and Structures/Materiaux et Constructions, | Περίληψη: | The impact of a thin layer of a ductile fiber-reinforced concrete referred to as engineered cementitious composites (ECC) on unreinforced masonry (URM) prisms and beams has been evaluated. The objective of the research was to characterize the performance and potential benefits of using ECC to retrofit URM with eventual application to masonry infill walls in non-ductile reinforced concrete frames. Compression tests of masonry prisms and flexural tests of masonry beams with different ECC retrofit schemes were conducted. The variables studied were the use of wall anchors to improve the ECC-masonry bond and alternate steel reinforcement ratios within the ECC layer in the form of welded wire fabric. The ECC retrofit was found to increase the strength and stiffness of URM prisms by 45 and 53 %, respectively compared to those of a plain specimen. When wall anchors were installed on the masonry specimens, the bond between the ECC layer and the masonry surface was improved. Four-point bending tests indicated that the strength and more importantly the ductility of an ECC retrofitted brick beam are increased significantly, especially when light reinforcement is added to the ECC layer, relative to an URM beam. Analytical models for estimating the strength and stiffness of ECC retrofitted masonry specimens are proposed and evaluated. | URI: | https://hdl.handle.net/20.500.14279/9746 | ISSN: | 13595997 | DOI: | 10.1617/s11527-013-0138-x | Rights: | © RILEM | Type: | Article | Affiliation: | Cyprus University of Technology Stanford University |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
19
checked on 6 Νοε 2023
WEB OF SCIENCETM
Citations
50
14
Last Week
1
1
Last month
0
0
checked on 29 Οκτ 2023
Page view(s)
449
Last Week
1
1
Last month
2
2
checked on 21 Νοε 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα