Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/9576
Τίτλος: | MRI-compatible positioning device for guiding a focused ultrasound system for transrectal treatment of prostate cancer | Συγγραφείς: | Yiallouras, Christos Mylonas, Nicos Damianou, Christakis A. |
Major Field of Science: | Medical and Health Sciences | Field Category: | Medical Engineering | Λέξεις-κλειδιά: | MRI;Prostate;Ultrasound | Ημερομηνία Έκδοσης: | 1-Ιου-2014 | Πηγή: | International Journal of Computer Assisted Radiology and Surgery, 2014, vol. 9, no. 4, pp. 745-753 | Volume: | 9 | Issue: | 4 | Start page: | 745 | End page: | 753 | Περιοδικό: | International Journal of Computer Assisted Radiology and Surgery | Περίληψη: | Background : High-intensity focused ultrasound (HIFU) is a promising treatment method for many common cancers, including prostate cancer. Magnetic resonance image (MRI) guidance of HIFU permits targeting and monitoring of therapy. A prototype MRI-compatible positioning device that navigates a HIFU transducer was designed, fabricated and tested. Materials and methods : The positioning device has two PC-controlled and one manually driven stage that allow endorectal access to the prostate. The positioning device was constructed using a 3-D rapid prototype manufacturing device. Software was developed that controls the motion of the positioning device and enables activation of a HIFU transducer. In vitro testing of the system was performed in a 1.5T MRI scanner using ex vivo turkey tissue. Optical encoders were employed to enhance the accuracy of this positioning device. Result : The positioning device was successfully tested for MRI compatibility. The movement error of the positioning device is approximately 20 μm. The robot has the ability to accurately move the transducer for creation of discrete and overlapping lesions. Conclusion : An MRI-compatible HIFU positioning system was developed that has the ability to create thermal lesions with MRI guidance for endorectal treatment of prostate cancer. | URI: | https://hdl.handle.net/20.500.14279/9576 | ISSN: | 18616410 | DOI: | 10.1007/s11548-013-0964-x | Rights: | © Springer Nature | Type: | Article | Affiliation: | Cyprus University of Technology Frederick Research Center Therapeutic Ultrasound |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
24
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
20
22
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s) 20
470
Last Week
0
0
Last month
5
5
checked on 22 Δεκ 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα