Title: MRI-compatible bone phantom for evaluating ultrasonic thermal exposures
Authors: Menikou, Georgios 
Yiannakou, Marinos 
Yiallouras, Christos 
Ioannides, Cleanthis 
Damianou, Christakis A. 
metadata.dc.contributor.other: Γιαννακού, Μαρίνος
Γιάλλουρας, Χρήστος
Δαμιανού, Χριστάκης Α.
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Keywords: Bone;Cancer;MRI;Ultrasound
Issue Date: 1-Sep-2016
Source: Ultrasonics, 2016, vol. 71, pp. 12-19
Volume: 71
Start page: 12
End page: 19
Journal: Ultrasonics 
Abstract: Objective The goal of the proposed study was the development of a magnetic resonance imaging (MRI) compatible bone phantom suitable for evaluating focused ultrasound protocols. Materials and methods High resolution CT images were used to segment femur bone. The segmented model was manufactured with (Acrylonitrile Butadiene Styrene) ABS plastic using a 3-D printer. The surrounding skeletal muscle tissue was mimicked using an agar-silica-evaporated milk gel (2% w/v-2% w/v-40% v/v). MR thermometry was used to evaluate the exposures of the bone phantom to focused ultrasound. Results The estimated agar-silica-evaporated milk gel's T1 and T2 relaxation times in a 1.5 T magnetic field were 776 ms and 66 ms respectively. MR thermometry maps indicated increased temperature adjacent to the bone, which was also shown in situations of real bone/tissue interfaces. Conclusion Due to growing interest of using MRI guided Focused Ultrasound Surgery (MRgFUS) in palliating bone cancer patients at terminal stages of the disease, the proposed bone phantom can be utilized as a very useful tool for evaluating ultrasonic protocols, thus minimizing the need for animal models. The estimated temperature measured and its distribution near the bone phantom/agar interface which was similar to temperatures recorded in real bone ablation with FUS, confirmed the phantom's functionality.
URI: https://hdl.handle.net/20.500.14279/9371
ISSN: 0041624X
DOI: 10.1016/j.ultras.2016.05.020
Rights: © Elsevier
Type: Article
Affiliation : City University London 
Cyprus University of Technology 
Ygia Polyclinic Hospital 
Publication Type: Peer Reviewed
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

SCOPUSTM   
Citations

14
checked on Nov 9, 2023

WEB OF SCIENCETM
Citations

12
Last Week
0
Last month
1
checked on Oct 29, 2023

Page view(s) 50

428
Last Week
0
Last month
2
checked on Dec 22, 2024

Google ScholarTM

Check

Altmetric


Items in KTISIS are protected by copyright, with all rights reserved, unless otherwise indicated.