Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/9094
Τίτλος: | In vivo monitoring of the inflammatory response in a stented mouse aorta model | Συγγραφείς: | Kapnisis, Konstantinos Pitsillides, Costas Prokopi, Marianna Lapathitis, George Karaiskos, Christos Eleftheriou, Polyvios Brott, Brigitta C. Anderson, Peter G. Lemons, Jack E. Anayiotos, Andreas |
metadata.dc.contributor.other: | Καπνίσης, Κωνσταντίνος Πιτσιλλίδης, Κώστας Αναγιωτός, Ανδρέας |
Major Field of Science: | Medical and Health Sciences | Field Category: | Clinical Medicine | Λέξεις-κλειδιά: | In vivo imaging;Inflammation;Mouse stent model;Stent corrosion | Ημερομηνία Έκδοσης: | 1-Ιαν-2016 | Πηγή: | Journal of Biomedical Materials Research - Part A, 2016, vol. 104, no. 1, pp. 227-238 | Volume: | 1204 | Issue: | 1 | Start page: | 227 | End page: | 238 | Περιοδικό: | Journal of Biomedical Materials Research - Part A | Περίληψη: | The popularity of vascular stents continues to increase for a variety of applications, including coronary, lower limb, renal, carotid, and neurovascular disorders. However, their clinical effectiveness is hindered by numerous postdeployment complications, which may stimulate inflammatory and fibrotic reactions. The purpose of this study was to evaluate the vessel inflammatory response via in vivo imaging in a mouse stent implantation model. Corroded and noncorroded self-expanding miniature nitinol stents were implanted in mice abdominal aortas, and novel in vivo imaging techniques were used to assess trafficking and accumulation of fluorescent donor monocytes as well as cellular proliferation at the implantation site. Monocytes were quantitatively tracked in vivo and found to rapidly clear from circulation within hours after injection. Differences were found between the test groups with respect to the numbers of recruited monocytes and the intensity of the resulting fluorescent signal. Image analysis also revealed a subtle increase in matrix metalloproteinase activity in corroded compared with the normal stented aortas. In conclusion, this study has been successful in developing a murine stent inflammation model and applying novel in vivo imaging tools and methods to monitor the complex biological processes of the host vascular wall response. | URI: | https://hdl.handle.net/20.500.14279/9094 | ISSN: | 15493296 | DOI: | 10.1002/jbm.a.35560 | Rights: | © Wiley | Type: | Article | Affiliation: | Cyprus University of Technology Trojantec Ltd Cyprus Institute of Neurology and Genetics University of Alabama at Birmingham |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
9
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
50
9
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s)
534
Last Week
0
0
Last month
3
3
checked on 2 Φεβ 2025
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα