Τίτλος: | Modeling and assessment of the efficiency of horizontal and vertical ground heat exchangers | Συγγραφείς: | Florides, Georgios A. Iosif-Stylianou, Iosifina Tassou, Savvas A. Zomeni, Zomenia Tsiolakis, Efthymios Pouloupatis, Panayiotis Kalogirou, Soteris A. Christodoulides, Paul Messaritis, Vassilios Panagiotou, Gregoris Theofanous, Elisavet |
Major Field of Science: | Engineering and Technology | Field Category: | Electrical Engineering - Electronic Engineering - Information Engineering | Λέξεις-κλειδιά: | Horizontal GHE (ground heat exchanger);Vertical GHE;Modeling;Heat pumps | Ημερομηνία Έκδοσης: | 1-Σεπ-2013 | Πηγή: | Energy, 2013, vol. 58, pp. 655–663 | Volume: | 58 | Start page: | 655 | End page: | 663 | Περιοδικό: | Energy | Περίληψη: | This paper describes the mathematical modeling of vertical and horizontal GHEs (ground heat exchangers) and compares their efficiency. The model used calculates the heat flow in the fluid, tubes, grout and ground. The vertical U-tube GHE is represented by two 100 m lines, embedded in four different types of ground with an additional bottom base. The horizontal GHE consists of four 50 m tube lines embedded in three ground layers. The initial ground temperature for all cases examined matches real data acquired in June at a location in Cyprus and the simulation results for the vertical GHE are validated using measured data showing very good agreement. Further simulations with the vertical GHE show that when the initial ground temperature rises, the mean temperature of the GHE fluid increases proportionally. Comparisons between horizontal and vertical GHEs reveal that under the same operating conditions and center-to-center distances of the tubes, the vertical GHE keeps a much lower mean temperature. Simulations for a horizontal GHE, for a 50-h of continuous operation period and 24 °C initial ground temperature, show that the mean fluid temperature can remain lower than that of the vertical GHE if the center-to-center distance of the tubes increases to 1 m. | URI: | https://hdl.handle.net/20.500.14279/4125 | ISSN: | 18736785 | DOI: | 10.1016/j.energy.2013.05.053 | Rights: | © Elsevier | Type: | Article | Affiliation: | Cyprus University of Technology Ministry of Agriculture, Rural Development and Environment, Cyprus Brunel University London |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
42
checked on 5 Νοε 2023
WEB OF SCIENCETM
Citations
50
40
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s) 20
465
Last Week
1
1
Last month
3
3
checked on 22 Δεκ 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα