Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/3685
Τίτλος: | Nuchal translucency and major congenital heart defects in fetuses with normal karyotype: a meta‐analysis | Συγγραφείς: | Sotiriadis, Alexandros Papatheodorou, Stefania Eleftheriades, Makarios I. Makrydimas, George V. |
Major Field of Science: | Medical and Health Sciences | Field Category: | Clinical Medicine | Λέξεις-κλειδιά: | Cardiac defects;Meta-analysis;Nuchal translucency;Screening;Ultrasound | Ημερομηνία Έκδοσης: | 18-Απρ-2013 | Πηγή: | Ultrasound in Obstetrics and Gynecology, 2013, vol. 42, no. 4, pp. 383-389 | Volume: | 42 | Issue: | 4 | Start page: | 383 | End page: | 389 | Περιοδικό: | Ultrasound in Obstetrics and Gynecology | Περίληψη: | Objective: To pool published data regarding the sensitivity and specificity of nuchal translucency (NT) in the diagnosis of major congenital heart defects (CHDs) in fetuses with normal karyotype. Methods: MEDLINE and Scopus searches using combinations of the terms 'nuchal' and 'cardiac*' were complemented by perusal of references of the retrieved articles and an additional automated search using the 'search for related articles' function on PubMed. Only fetuses with normal karyotype and major CHDs were analyzed. Weighted estimates were made and summary receiver-operating characteristics curves were constructed. Results: The analysis included 20 studies (205 232 fetuses; 537 cases with major CHDs). The pooled sensitivity and specificity of NT > 95th centile for diagnosis of major CHDs was 44.4% (95% CI, 39.5-49.5) and 94.5% (95% CI, 94.4-94.6), respectively. The pooled sensitivity and specificity of NT > 99th centile was 19.5% (95% CI, 15.9-23.5) and 99.1% (95% CI, 99.1-99.2), respectively. For the subgroup of studies in which NT was measured by Fetal Medicine Foundation-certified operators, the pooled sensitivity and specificity of NT > 95th centile was 45.6% (95% CI, 39.6-51.7) and 94.7% (95% CI, 94.6-94.9), respectively. The corresponding estimates for NT > 99th centile were 21.0% (95%CI, 16.5-26.1) and 99.2% (95% CI, 99.2-99.3). The pooled positive likelihood ratio for NT > 99th centile was 30.5 (95% CI, 24.3-38.6). There was high across-studies heterogeneity for most estimates. Conclusion Approximately 44% of chromosomally normal fetuses with CHDs have NT > 95th centile and 20% have NT > 99th centile. However, there is high heterogeneity across studies, which largely remains even in subgroup analyses of studies of apparently similar design, potentially indicating the presence of some residual unidentified bias. | URI: | https://hdl.handle.net/20.500.14279/3685 | ISSN: | 14690705 | DOI: | 10.1002/uog.12488 | Rights: | © Wiley | Type: | Article | Affiliation: | Aristotle University of Thessaloniki Cyprus University of Technology Embryocare University of Ioannina |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
57
checked on 9 Νοε 2023
WEB OF SCIENCETM
Citations
50
47
Last Week
0
0
Last month
2
2
checked on 31 Οκτ 2023
Page view(s) 20
487
Last Week
0
0
Last month
1
1
checked on 22 Δεκ 2024
Google ScholarTM
Check
Altmetric
Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα