Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/3685
Τίτλος: Nuchal translucency and major congenital heart defects in fetuses with normal karyotype: a meta‐analysis
Συγγραφείς: Sotiriadis, Alexandros 
Papatheodorou, Stefania 
Eleftheriades, Makarios I. 
Makrydimas, George V. 
Major Field of Science: Medical and Health Sciences
Field Category: Clinical Medicine
Λέξεις-κλειδιά: Cardiac defects;Meta-analysis;Nuchal translucency;Screening;Ultrasound
Ημερομηνία Έκδοσης: 18-Απρ-2013
Πηγή: Ultrasound in Obstetrics and Gynecology, 2013, vol. 42, no. 4, pp. 383-389
Volume: 42
Issue: 4
Start page: 383
End page: 389
Περιοδικό: Ultrasound in Obstetrics and Gynecology 
Περίληψη: Objective: To pool published data regarding the sensitivity and specificity of nuchal translucency (NT) in the diagnosis of major congenital heart defects (CHDs) in fetuses with normal karyotype. Methods: MEDLINE and Scopus searches using combinations of the terms 'nuchal' and 'cardiac*' were complemented by perusal of references of the retrieved articles and an additional automated search using the 'search for related articles' function on PubMed. Only fetuses with normal karyotype and major CHDs were analyzed. Weighted estimates were made and summary receiver-operating characteristics curves were constructed. Results: The analysis included 20 studies (205 232 fetuses; 537 cases with major CHDs). The pooled sensitivity and specificity of NT > 95th centile for diagnosis of major CHDs was 44.4% (95% CI, 39.5-49.5) and 94.5% (95% CI, 94.4-94.6), respectively. The pooled sensitivity and specificity of NT > 99th centile was 19.5% (95% CI, 15.9-23.5) and 99.1% (95% CI, 99.1-99.2), respectively. For the subgroup of studies in which NT was measured by Fetal Medicine Foundation-certified operators, the pooled sensitivity and specificity of NT > 95th centile was 45.6% (95% CI, 39.6-51.7) and 94.7% (95% CI, 94.6-94.9), respectively. The corresponding estimates for NT > 99th centile were 21.0% (95%CI, 16.5-26.1) and 99.2% (95% CI, 99.2-99.3). The pooled positive likelihood ratio for NT > 99th centile was 30.5 (95% CI, 24.3-38.6). There was high across-studies heterogeneity for most estimates. Conclusion Approximately 44% of chromosomally normal fetuses with CHDs have NT > 95th centile and 20% have NT > 99th centile. However, there is high heterogeneity across studies, which largely remains even in subgroup analyses of studies of apparently similar design, potentially indicating the presence of some residual unidentified bias.
URI: https://hdl.handle.net/20.500.14279/3685
ISSN: 14690705
DOI: 10.1002/uog.12488
Rights: © Wiley
Type: Article
Affiliation: Aristotle University of Thessaloniki 
Cyprus University of Technology 
Embryocare 
University of Ioannina 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

57
checked on 9 Νοε 2023

WEB OF SCIENCETM
Citations 50

47
Last Week
0
Last month
2
checked on 31 Οκτ 2023

Page view(s) 20

458
Last Week
0
Last month
7
checked on 11 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα