Title: Design optimization of a solar system integrated double-skin façade for a clustered housing unit
Authors: Barone, Giovanni 
Vassiliades, Constantinos 
Elia, Christina 
Savvides, Andreas L. 
Kalogirou, Soteris A. 
Major Field of Science: Engineering and Technology
Field Category: Mechanical Engineering
Keywords: Building integrated photovoltaic-thermal;Building integration;Double façade;Energy analysis;Sustainable architecture
Issue Date: 1-Oct-2023
Source: Renewable Energy, 2023, vol. 215
Volume: 215
Journal: Renewable Energy 
Abstract: The study compares a conventional double façade (DF), a building-integrated photovoltaic double façade (BIPV DF), and building-integrated photovoltaic thermal double façade (BIPVT DF), by considering the impact of the depth of the cavity between the photovoltaic system and the façade. The problematization aims at augmenting the function of an interstitial spaces between building envelope and programmed space both in terms of spatial expansion, but also in terms of energy production. The approach involves examining this space in terms of its spatial parameters and ability to accept an architecturally integrated solar system. To conduct the present analyses, three distinct systems were employed and applied to a sample thermal zone, where the cavity space shaped by the double façade was considered as a veranda space. The energy systems were modelled utilizing the commercial software DesignBuilder, and various dynamic simulations were performed using the building energy simulation software EnergyPlus for a representative South-Eastern Mediterranean weather zone. A parametric analysis was conducted, which involved varying the cavity depths from 0.25 m to 1.50 m. Results show that the conventional DF system demonstrates lower heating demands than the other systems, whereas the opposites occur for the cooling needs. Furthermore, an increase in the cavity depth between the PV system and the façade resulted in an increase in heating thermal loads and a decrease in cooling loads. The primary energy minimization approach provided interesting results, including the optimal depth cavity of the veranda (0.97 m).
URI: https://hdl.handle.net/20.500.14279/30648
ISSN: 09601481
DOI: 10.1016/j.renene.2023.119023
Rights: © Elsevier
Attribution-NonCommercial-NoDerivatives 4.0 International
Type: Article
Affiliation : University of Naples Federico II 
Neapolis University Pafos 
University of Cyprus 
Cyprus University of Technology 
Publication Type: Peer Reviewed
Appears in Collections:Άρθρα/Articles

CORE Recommender
Show full item record

SCOPUSTM   
Citations 50

5
checked on Mar 14, 2024

Page view(s)

161
Last Week
1
Last month
1
checked on Dec 21, 2024

Google ScholarTM

Check

Altmetric


This item is licensed under a Creative Commons License Creative Commons