Τίτλος: Disdrometer calibration using an adaptive signal processing algorithm
Συγγραφείς: Kasparis, Takis 
Kourtellis, Achilleas G. 
Jones, Linwood W. 
metadata.dc.contributor.other: Κασπαρής, Τάκης
Major Field of Science: Engineering and Technology
Field Category: Electrical Engineering - Electronic Engineering - Information Engineering
Λέξεις-κλειδιά: Calibration;Transducers;Algorithms;Signal processing;Piezoelectric materials
Ημερομηνία Έκδοσης: Σεπ-2005
Πηγή: Proceedings of MTS/IEEE OCEANS, 2005, vol. 3,pp. 2572-2577
Conference: Proceedings of MTS/IEEE OCEANS 
Περίληψη: Disdrometers are considered exotic instruments and provide valuable information. As such, their price tag is also high. Impact disdrometers are instruments that produce an electrical impulse output related to the mass of a rain drop colliding at terminal velocity with a sensor. The produced electrical impulse signal amplitude and energy are related to the drop diameters. This relation is in general non-linear and depends heavily on the type of transducer used. Mechanical structure imperfections and electrical tolerances dictate the need for the individual calibration of each instrument in an attempt to create calibration curves that convert impulse amplitudes to equivalent drop diameters. Conventional calibration techniques using drop towers have been a tedious process to say the least. A proposed alternative calibration technique utilizing an adaptive signal processing algorithm eliminates the need of a single drop calibration. An accumulation rain gauge provides a reference signal to the disdrometer that is used for adaptive training and optimization of a model based calibration function. In this paper we describe a prototype low-cost disdrometer implementation at the University of Central Florida. A prototype impact sensor was built using an array of piezoelectric elements encapsulated in water resistant material. For the data acquisition and processing we use the soundboard of a general purpose computer. The signal processing algorithms and Matlab implementation will be described. Data have been collected and processed and results will be presented. Future plans on developing a low cost disdrometer will also be discussed. The availability of affordable disdrometers will benefit NASA's upcoming GPM program, as well as many other meteorological agencies.
ISBN: 0-933957-34-3
ISSN: 0197-7385
DOI: 10.1109/OCEANS.2005.1640158
Type: Conference Papers
Affiliation: University of Central Florida 
Affiliation: University of Central Florida 
Εμφανίζεται στις συλλογές:Δημοσιεύσεις σε συνέδρια /Conference papers or poster or presentation

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
disdrometer calibration using an adaptive signal .pdf900.15 kBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations 10

4
checked on 6 Νοε 2023

Page view(s) 50

403
Last Week
2
Last month
9
checked on 9 Μαϊ 2024

Download(s) 10

377
checked on 9 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Όλα τα τεκμήρια του δικτυακού τόπου προστατεύονται από πνευματικά δικαιώματα