Τίτλος: | Assessment of indoor and outdoor air quality in primary schools of Cyprus during the COVID-19 pandemic measures in May-July 2021 | Συγγραφείς: | Konstantinou, Corina Constantinou, Andria Kleovoulou, Eleni G. Kyriacou, Alexis Kakoulli, Christina Milis, George Michaelides, Michalis Makris, Konstantinos C. |
Major Field of Science: | Medical and Health Sciences | Field Category: | Health Sciences | Λέξεις-κλειδιά: | COVID–19 measures;Environmental pollutants;Exposome;Indoor air quality;School;School | Ημερομηνία Έκδοσης: | Μαΐ-2022 | Πηγή: | Heliyon, 2022, vol. 8, iss. 5 | Volume: | 8 | Issue: | 5 | Περίληψη: | Combined pollutant effects from indoor and outdoor sources on children's health, while being at school have not been holistically tackled. The aim of the School Temperature and Environmental Pollutants Study (STEPS) was to perform a school population representative assessment of indoor air quality (IAQ) in primary schools of densely and intermediate populated areas of Cyprus (n = 42). The study took place during May-July 2021 when a school-specific COVID-19 protocol was in place. Questionnaire-based characteristics of schools/classrooms were collected along with 24/48-h long IAQ monitoring of air temperature, relative humidity (RH), particulate matter (PM), carbon dioxide (CO2) and volatile organic compounds (VOCs), using low-cost sensors. Mixed effect models assessed the IAQ determinants during school hours. Indoor PM, temperature, RH and VOCs increased with progressing school periods in the day, while indoor CO2 decreased. Indoor RH and CO2 were negatively associated with % open windows, while indoor PM2.5 was positively associated. Most of school time (85%), indoor air temperature exceeded the recommended upper limit (27 °C), while a third of indoor PM2.5 (24-h) measurements exceeded 15 μg/m3. The interplay of clean indoor air with adequate ventilation and adaptation to heat stress in schools is important and its comprehensive characterization requires holistic methodological approaches and tools. | URI: | https://hdl.handle.net/20.500.14279/29674 | ISSN: | 24058440 | DOI: | 10.1016/j.heliyon.2022.e09354 | Rights: | © The Authors Attribution-NonCommercial-NoDerivatives 4.0 International |
Type: | Article | Affiliation: | Cyprus University of Technology LELANTUS Innovations Ltd PHOEBE Research & Innovation Ltd |
Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
makris constantinos 8.pdf | Full text | 779.97 kB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
8
checked on 2 Φεβ 2024
WEB OF SCIENCETM
Citations
4
Last Week
0
0
Last month
0
0
checked on 1 Νοε 2023
Page view(s)
182
Last Week
0
0
Last month
10
10
checked on 2 Φεβ 2025
Download(s) 50
66
checked on 2 Φεβ 2025
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons