Τίτλος: | Strain Measurement in Hyrax Appliances Using FBG Sensors in a 3D-Printed Human Maxillary Model | Συγγραφείς: | Coimbra, Wagner Oliveira, Pedro Theodosiou, Antreas Marques, Carlos Kalli, Kyriacos Leal-Junior, Arnaldo |
Major Field of Science: | Engineering and Technology | Field Category: | Electrical Engineering - Electronic Engineering - Information Engineering | Λέξεις-κλειδιά: | Fiber Bragg grating sensors;strain measurement;orthodontic biomechanics;rapid maxillary expansion | Ημερομηνία Έκδοσης: | 15-Αυγ-2022 | Πηγή: | IEEE Photonics Technology Letters, 2022, vol. 34, iss. 15 | Volume: | 34 | Issue: | 15 | Περιοδικό: | IEEE Photonics Technology Letters | Περίληψη: | This letter presents a method of measuring the strain during rapid maxillary expansion (RME) using fiber Bragg grating (FBG) sensors. The activation of the central jackscrew of the Hyrax expander provides the forces required to expand the maxilla that are transmitted to the teeth by a metallic wire. The strain resulted from the opening forces was measured by a FBG sensor bonded to the posterior arm of the appliance. A proof of concept is shown using a 3D printed maxillary model of the biomechanical structure of a human maxilla, in which the appliance was mounted. The sensor was able to measure static and dynamic events, such as the strain accumulation and viscoelastic strain patterns. An increase in the strain is observed as the number of activations increases. A fast decrease in the strain between activations was also observed. In spite of using a plastic model with viscoelastic properties, this decrease may be related to limitations of the central jackscrew. The instrumentation of the Hyrax expanders using FBG sensors assists in clinical studies on the biomechanics and the efficiency of RME. Different expanders can be compared using the present sensor, and tests on their components, especially the central jackscrew, contributes to improvements or new procedures on such treatments. | URI: | https://hdl.handle.net/20.500.14279/29540 | ISSN: | 10411135 | DOI: | 10.1109/LPT.2022.3190195 | Rights: | © IEEE Attribution-NonCommercial-NoDerivatives 4.0 International |
Type: | Article | Affiliation: | Cyprus University of Technology Federal University of Espirito Santo Federal University of Rio de Janeiro Universidade de Aveiro Federal University of Espirito Santo |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
CORE Recommender
SCOPUSTM
Citations
50
1
checked on 14 Μαρ 2024
WEB OF SCIENCETM
Citations
1
Last Week
0
0
Last month
checked on 29 Οκτ 2023
Page view(s)
103
Last Week
3
3
Last month
9
9
checked on 9 Μαϊ 2024
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons