Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο:
https://hdl.handle.net/20.500.14279/27354
Τίτλος: | Environmental Impact of Ground Source Heat Pump Systems: A Comparative Investigation From South to North Europe | Συγγραφείς: | Aresti, Lazaros Florides, Georgios A. Skaliontas, Andreas Christodoulides, Paul |
Major Field of Science: | Engineering and Technology | Field Category: | Environmental Engineering | Λέξεις-κλειδιά: | GSHP;Environmental impact;GHE;OpenLCA;Geothermal energy;LCA;CO2 payback period | Ημερομηνία Έκδοσης: | 4-Ιου-2022 | Πηγή: | Frontiers in Built Environment, vol. 8, articl. no. 914227 | Volume: | 8 | Περιοδικό: | Frontiers in Built Environment | Περίληψη: | Ground Heat Exchangers (GHEs), buried in the ground either horizontally or vertically (in a borehole), are coupled with a heat pump to form a Ground Source Heat Pump (GSHP) system, which is a type of Renewable Energy System that exploits geothermal energy for space heating and cooling. GSHP systems are proposed as an alternative to conventional Air Source Heat Pumps (ASHPs) as they exhibit a higher efficiency. In this study, this difference in efficiency is tested in order to determine how the systems perform in terms of environmental impact. Three types of GSHP systems (with different GHE configuration), each compared to ASHPs, undergo a Life Cycle Analysis using the ReCiPe method from both mid-point and end-point perspectives. The heating and cooling loads required for a single residential building of area 220 m2, with nearly Zero Energy Building technical characteristics, is used as a Functional Unit, for seven cases (locations/countries) from South to North Europe. Additionally, a Simple Payback Period method is employed to investigate the CO2 payback time for the GSHPs. It is concluded that the use of GSHP systems in residential buildings, even with nZEB (nearly Zero Energy Buildings) characteristics of low heating/cooling demand, can be a more environmentally friendly solution than that of an ASHP system, depending on the factors affecting the system, namely the ground thermal characteristics, the heating/cooling demand, the heating/cooling peak loads and electricity mix. | URI: | https://hdl.handle.net/20.500.14279/27354 | ISSN: | 22973362 | DOI: | 10.3389/fbuil.2022.914227 | Rights: | © Aresti, Florides, Skaliontas and Christodoulides. This is an open access article distributed under the terms of the Creative Commons Attribution License Attribution-NonCommercial-NoDerivatives 4.0 International |
Type: | Article | Affiliation: | Cyprus University of Technology | Publication Type: | Peer Reviewed |
Εμφανίζεται στις συλλογές: | Άρθρα/Articles |
Αρχεία σε αυτό το τεκμήριο:
Αρχείο | Περιγραφή | Μέγεθος | Μορφότυπος | |
---|---|---|---|---|
2022 Aresti et al. fbuil-08-914227.pdf | Fulltext | 1.59 MB | Adobe PDF | Δείτε/ Ανοίξτε |
CORE Recommender
SCOPUSTM
Citations
4
checked on 14 Μαρ 2024
WEB OF SCIENCETM
Citations
1
Last Week
0
0
Last month
0
0
checked on 29 Οκτ 2023
Page view(s)
203
Last Week
0
0
Last month
2
2
checked on 22 Δεκ 2024
Download(s)
150
checked on 22 Δεκ 2024
Google ScholarTM
Check
Altmetric
Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons