Παρακαλώ χρησιμοποιήστε αυτό το αναγνωριστικό για να παραπέμψετε ή να δημιουργήσετε σύνδεσμο προς αυτό το τεκμήριο: https://hdl.handle.net/20.500.14279/27354
Τίτλος: Environmental Impact of Ground Source Heat Pump Systems: A Comparative Investigation From South to North Europe
Συγγραφείς: Aresti, Lazaros 
Florides, Georgios A. 
Skaliontas, Andreas 
Christodoulides, Paul 
Major Field of Science: Engineering and Technology
Field Category: Environmental Engineering
Λέξεις-κλειδιά: GSHP;Environmental impact;GHE;OpenLCA;Geothermal energy;LCA;CO2 payback period
Ημερομηνία Έκδοσης: 4-Ιου-2022
Πηγή: Frontiers in Built Environment, vol. 8, articl. no. 914227
Volume: 8
Περιοδικό: Frontiers in Built Environment 
Περίληψη: Ground Heat Exchangers (GHEs), buried in the ground either horizontally or vertically (in a borehole), are coupled with a heat pump to form a Ground Source Heat Pump (GSHP) system, which is a type of Renewable Energy System that exploits geothermal energy for space heating and cooling. GSHP systems are proposed as an alternative to conventional Air Source Heat Pumps (ASHPs) as they exhibit a higher efficiency. In this study, this difference in efficiency is tested in order to determine how the systems perform in terms of environmental impact. Three types of GSHP systems (with different GHE configuration), each compared to ASHPs, undergo a Life Cycle Analysis using the ReCiPe method from both mid-point and end-point perspectives. The heating and cooling loads required for a single residential building of area 220 m2, with nearly Zero Energy Building technical characteristics, is used as a Functional Unit, for seven cases (locations/countries) from South to North Europe. Additionally, a Simple Payback Period method is employed to investigate the CO2 payback time for the GSHPs. It is concluded that the use of GSHP systems in residential buildings, even with nZEB (nearly Zero Energy Buildings) characteristics of low heating/cooling demand, can be a more environmentally friendly solution than that of an ASHP system, depending on the factors affecting the system, namely the ground thermal characteristics, the heating/cooling demand, the heating/cooling peak loads and electricity mix.
URI: https://hdl.handle.net/20.500.14279/27354
ISSN: 22973362
DOI: 10.3389/fbuil.2022.914227
Rights: © Aresti, Florides, Skaliontas and Christodoulides. This is an open access article distributed under the terms of the Creative Commons Attribution License
Attribution-NonCommercial-NoDerivatives 4.0 International
Type: Article
Affiliation: Cyprus University of Technology 
Εμφανίζεται στις συλλογές:Άρθρα/Articles

Αρχεία σε αυτό το τεκμήριο:
Αρχείο Περιγραφή ΜέγεθοςΜορφότυπος
2022 Aresti et al. fbuil-08-914227.pdfFulltext1.59 MBAdobe PDFΔείτε/ Ανοίξτε
CORE Recommender
Δείξε την πλήρη περιγραφή του τεκμηρίου

SCOPUSTM   
Citations

4
checked on 14 Μαρ 2024

WEB OF SCIENCETM
Citations

1
Last Week
0
Last month
0
checked on 29 Οκτ 2023

Page view(s)

179
Last Week
2
Last month
10
checked on 12 Μαϊ 2024

Download(s)

92
checked on 12 Μαϊ 2024

Google ScholarTM

Check

Altmetric


Αυτό το τεκμήριο προστατεύεται από άδεια Άδεια Creative Commons Creative Commons